Suppr超能文献

基于免疫分析的类固醇激素测量外部质量评估的纵向分析表明标准化方面有改进的潜力。

Longitudinal analysis of external quality assessment of immunoassay-based steroid hormone measurement indicates potential for improvement in standardization.

作者信息

Vierbaum Laura, Weiss Nathalie, Kaiser Patricia, Kremser Marcel, Wenzel Folker, Thevis Mario, Schellenberg Ingo, Luppa Peter B

机构信息

INSTAND e.V., Society for Promoting Quality Assurance in Medical Laboratories, Duesseldorf, Germany.

Faculty of Medical and Life Sciences, Furtwangen University, Villingen-Schwenningen, Germany.

出版信息

Front Mol Biosci. 2024 Jan 31;11:1345356. doi: 10.3389/fmolb.2024.1345356. eCollection 2024.

Abstract

As hormonal disorders are linked to several diseases, the accurate quantitation of steroid hormone levels in serum is crucial in order to provide patients with a reliable diagnosis. Mass spectrometry-based methods are regarded as having the highest level of specificity and sensitivity. However, immunoassays are more commonly used in routine diagnostics to measure steroid levels as they are more cost effective and straightforward to conduct. This study analyzes the external quality assessment results for the measurement of testosterone, progesterone and 17β-estradiol in serum using immunoassays between early 2020 and May 2022. As reference measurement procedures are available for the three steroid hormones, the manufacturer-specific biases were normalized to the reference measurement values. The manufacturer-specific coefficients of variation were predominantly inconspicuous, below 20% for the three hormones when outliers are disregarded, however there were large differences between the various manufacturer collectives. For some collectives, the median bias to the respective reference measurement value was repeatedly greater than ±35%, which is the acceptance limit defined by the German Medical Association. In the case of testosterone and progesterone determination, some collectives tended to consistently over- or underestimate analyte concentrations compared to the reference measurement value, however, for 17β-estradiol determination, both positive and negative biases were observed. This insufficient level of accuracy suggests that cross-reactivity continues to be a fundamental challenge when antibody detection is used to quantify steroids with a high structural similarity. Distinct improvements in standardization are required to provide accurate analysis and thus, reliable clinical interpretations. The increased accuracy of the AX immunoassay for testosterone measurement, as observed in the INSTAND EQAs between 2020 and 2022, could be the result of a recalibration of the assay and raises hope for further improvement of standardization of immunoassay-based steroid hormone analyses in the coming years.

摘要

由于激素紊乱与多种疾病相关,准确测定血清中类固醇激素水平对于为患者提供可靠诊断至关重要。基于质谱的方法被认为具有最高的特异性和灵敏度。然而,免疫测定法在常规诊断中更常用于测量类固醇水平,因为它们更具成本效益且操作简单。本研究分析了2020年初至2022年5月期间使用免疫测定法测定血清中睾酮、孕酮和17β-雌二醇的外部质量评估结果。由于有这三种类固醇激素的参考测量程序,特定制造商的偏差已根据参考测量值进行了标准化。特定制造商的变异系数大多不明显,在忽略异常值的情况下,这三种激素的变异系数均低于20%,然而不同制造商群体之间存在很大差异。对于一些群体,与各自参考测量值的中位偏差反复大于±35%,这是德国医学协会定义的可接受限度。在睾酮和孕酮测定中,与参考测量值相比,一些群体倾向于持续高估或低估分析物浓度,然而,对于17β-雌二醇测定,观察到既有正偏差也有负偏差。这种准确性不足表明,当使用抗体检测来定量结构高度相似的类固醇时,交叉反应仍然是一个根本挑战。需要在标准化方面有明显改进,以提供准确的分析,从而得出可靠的临床解释。2020年至2022年期间在INSTAND EQA中观察到的AX免疫测定法用于睾酮测量的准确性提高,可能是该测定法重新校准的结果,并为未来几年基于免疫测定的类固醇激素分析标准化的进一步改进带来了希望。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验