Suppr超能文献

血栓波形态分析:从高凝状态到低凝状态:综述。

Clot Waveform Analysis: From Hypercoagulability to Hypocoagulability: A Review.

机构信息

From the Department of Medical Sciences and Public Health (F Marongiu, Ruberto, Barcellona) and Thrombosis and Haemostasis Unit (Barcellona), University of Cagliari, Cagliari, Italy.

Internal Medicine Unit, SS Trinità Hospital of Cagliari, Cagliari, Italy (S Marongiu).

出版信息

Arch Pathol Lab Med. 2024 Dec 1;148(12):1371-1375. doi: 10.5858/arpa.2023-0453-RA.

Abstract

CONTEXT.—: Prothrombin time (PT) and activated partial thromboplastin time (aPTT) are coagulative screening tests used for the diagnosis of several pathologic conditions, such as liver failure, coagulation factor deficiencies, anti-phospholipid antibodies (lupus anticoagulant), and factor VIII inhibitors. A new test was developed several years ago to detect the amount of thrombin generated during plasma clotting, using low tissue factor concentrations and fluorogenic substrates, and it has since been used successfully in conditions ranging from hypocoagulable to hypercoagulable states. However, the test is expensive and difficult to perform in nonspecialized laboratories, and efforts have thus been made to find an economic and easily implementable test suitable for routine use, even in nonspecialist laboratories.

OBJECTIVE.—: To evaluate clot waveform analysis (CWA) of PT and aPTT, aiming to show the dynamics of clot formation; that is, the "hidden" features of both tests. CWA can be implemented by using an automated coagulometer with dedicated software. The aim of this review was to evaluate whether CWA is able to detect both hypercoagulative and hypocoagulative states.

DATA SOURCES.—: Using MedLine, we searched and retrieved articles relating to CWA. We only considered articles published in English, but with no limits in terms of article type, publication year, or geography.

CONCLUSIONS.—: CWA was shown to be a reliable test in patients with both hypercoagulable and hypocoagulable states. It represents a simple and inexpensive global test that can easily provide information on the behavior of the coagulation system. Both the first and second derivatives are computed by using dedicated software implemented with an on-board algorithm in a routine automated coagulometer.

摘要

背景

凝血酶原时间(PT)和活化部分凝血活酶时间(aPTT)是用于诊断多种病理情况的凝血筛选试验,例如肝功能衰竭、凝血因子缺乏、抗磷脂抗体(狼疮抗凝剂)和因子 VIII 抑制剂。几年前开发了一种新的测试方法,用于检测血浆凝固过程中生成的凝血酶量,使用低组织因子浓度和荧光底物,此后已成功用于从低凝状态到高凝状态的各种情况。然而,该测试昂贵且难以在非专业实验室中进行,因此,人们一直在努力寻找一种经济且易于实施的测试方法,即使在非专业实验室中也可常规使用。

目的

评估 PT 和 aPTT 的凝块波型分析(CWA),旨在显示凝块形成的动力学;也就是说,这两种测试的“隐藏”特征。CWA 可以通过使用带有专用软件的自动化凝血仪来实现。本综述的目的是评估 CWA 是否能够检测到高凝状态和低凝状态。

数据来源

使用 MedLine 进行搜索并检索了与 CWA 相关的文章。我们仅考虑了以英文发表的文章,但不限制文章类型、发表年份或地理位置。

结论

CWA 已被证明可用于检测高凝状态和低凝状态的患者。它是一种可靠的简单且经济的整体测试,可以轻松提供有关凝血系统行为的信息。通过使用带有内置算法的专用软件,在常规的自动化凝血仪中计算出一阶导数和二阶导数。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验