Centre for Myopia Research, School of Optometry, The Hong Kong Polytechnic University, Hong Kong SAR, China.
Centre for Myopia Research, School of Optometry, The Hong Kong Polytechnic University, Hong Kong SAR, China
BMJ Open Ophthalmol. 2024 Feb 21;9(1):e001393. doi: 10.1136/bmjophth-2023-001393.
Full-field electroretinogram (ffERG) is an objective test to determine the electroretinal activities in response to light stimulation for investigating retinal physiology and diagnosing retinal diseases. This study aimed to establish a reference data set of photopic electroretinogram (ERG) of Chinese preschool children in Hong Kong to facilitate clinical and research studies.
Preschool children aged 3-7 years with normal vision were recruited from local kindergartens. Eye examinations, including cycloplegic spherical equivalent refraction (SER), axial length (AL) and keratometry (K) measurements, were performed. ffERGs of the International Society for Clinical Electrophysiology of Vision (ISCEV) standard photopic flash and 30-Hz flicker protocols were measured using RETeval with Sensor Strip skin electrodes. ERG waveform characteristics were extracted, and relationships between ERG, age, SER, AL and K were evaluated.
A total of 479 children completed the measurements (mean age: 5.0±0.9 years, 45.5% female). Mean, 95% CIs, 5th-95th percentile range of the ERG parameters were reported. Age was positively associated with amplitudes of b-wave and 30-Hz flicker (p<0.01), but negatively associated with implicit times of b-wave and 30-Hz flicker (p<0.01). AL was significantly associated with all amplitudes of a-wave, b-wave and 30-Hz flicker (p≤0.01) and implicit time of both a-wave and 30-Hz flicker (p<0.05). K was positively associated only with 30-Hz flicker amplitude (p=0.01), and no association between all responses and SER.
Reference data set of photopic ERG of Chinese preschool children was established. Cross-sectional investigations revealed associations between ERG, age, SER and AL, which were speculated to further implicate the role of retina in refractive error development.
全视野视网膜电图(ffERG)是一种客观测试方法,用于测量光刺激反应的视网膜电活动,以研究视网膜生理学和诊断视网膜疾病。本研究旨在建立香港学龄前儿童明视视网膜电图(ERG)的参考数据集,以方便临床和研究。
从当地幼儿园招募视力正常的 3-7 岁学龄前儿童。进行眼科检查,包括睫状肌麻痹等效球镜(SER)、眼轴(AL)和角膜曲率(K)测量。使用 RETeval 传感器带皮肤电极进行国际临床视觉电生理学学会(ISCEV)标准明视闪光和 30-Hz 闪烁协议的 ffERG 测量。提取 ERG 波形特征,并评估 ERG 与年龄、SER、AL 和 K 的关系。
共有 479 名儿童完成了测量(平均年龄:5.0±0.9 岁,45.5%为女性)。报告了 ERG 参数的平均值、95%置信区间、第 5 至 95 百分位范围。年龄与 b 波和 30-Hz 闪烁的振幅呈正相关(p<0.01),但与 b 波和 30-Hz 闪烁的潜伏期呈负相关(p<0.01)。AL 与 a 波、b 波和 30-Hz 闪烁的所有振幅以及 a 波和 30-Hz 闪烁的潜伏期均显著相关(p≤0.01)。K 仅与 30-Hz 闪烁振幅呈正相关(p=0.01),与所有反应和 SER 均无关联。
建立了中国学龄前儿童明视 ERG 的参考数据集。横断面研究揭示了 ERG、年龄、SER 和 AL 之间的关系,这被推测进一步暗示了视网膜在屈光不正发展中的作用。