Gunda Simon Takadiyi, Ng Tsam Kit Veronica, Liu Tsz-Ying, Chen Ziman, Han Xinyang, Chen Xiangyan, Pang Marco Yiu-Chung, Ying Michael Tin-Cheung
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR, China.
Department of Radiography, National University of Science and Technology (NUST), Ascot Bulawayo P.O. Box AC 939, Zimbabwe.
Diagnostics (Basel). 2024 Feb 10;14(4):387. doi: 10.3390/diagnostics14040387.
Cerebrovascular disease (CVD) poses a major public health and socio-economic burden worldwide due to its high morbidity and mortality rates. Accurate assessment of cerebral arteries' haemodynamic plays a crucial role in the diagnosis and treatment management of CVD. The study compared a non-imaging transcranial Doppler ultrasound (TCD) and transcranial color-coded Doppler ultrasound (with (cTCCD) and without (ncTCCD)) angle correction in quantifying middle cerebral arteries (MCAs) haemodynamic parameters. A cross-sectional study involving 50 healthy adults aged ≥ 18 years was conducted. The bilateral MCAs were insonated via three trans-temporal windows (TTWs-anterior, middle, and posterior) using TCD, cTCCD, and ncTCCD techniques. The MCA peak systolic velocity (PSV) and mean flow velocity (MFV) were recorded at proximal and distal imaging depths that could be visualised on TCCD with a detectable spectral waveform. A total of 152 measurements were recorded in 41 (82%) subjects with at least one-sided open TTW across the three techniques. The mean PSVs measured using TCD, ncTCCD, and cTCCD were 83 ± 18 cm/s, 81 ± 19 cm/s, and 93 ± 21 cm/s, respectively. There was no significant difference in PSV between TCD and ncTCCD (bias = 2 cm/s, = 1.000), whereas cTCCD yielded a significantly higher PSV than TCD and ncTCCD (bias = -10 cm/s, < 0.001; bias = -12 cm/s, ≤ 0.001, respectively). The bias in MFV between TCD and ncTCCD techniques was (bias = -0.5 cm/s; = 1.000), whereas cTCCD demonstrated a higher MFV compared to TCD and ncTCCD (bias = -8 cm/s, < 0.001; bias = -8 cm/s, ≤ 0.001, respectively). TCCD is a practically applicable imaging technique in assessing MCA blood flow velocities. cTCCD is more accurate and tends to give higher MCA blood flow velocities than non-imaging TCD and ncTCCD techniques. ncTCCD is comparable to non-imaging TCD and should be considered in clinical cases where using both TCD and TCCD measurements is needed.
脑血管疾病(CVD)因其高发病率和死亡率,在全球范围内构成了重大的公共卫生和社会经济负担。准确评估脑动脉血流动力学在CVD的诊断和治疗管理中起着至关重要的作用。本研究比较了非成像经颅多普勒超声(TCD)以及经颅彩色编码多普勒超声(有角度校正(cTCCD)和无角度校正(ncTCCD))在量化大脑中动脉(MCA)血流动力学参数方面的情况。开展了一项涉及50名年龄≥18岁健康成年人的横断面研究。使用TCD、cTCCD和ncTCCD技术,通过三个颞窗(前、中、后颞窗)对双侧MCA进行探测。在TCCD上可可视化且具有可检测频谱波形的近端和远端成像深度处记录MCA的收缩期峰值流速(PSV)和平均流速(MFV)。在41名(82%)至少有一侧颞窗开放的受试者中,通过这三种技术共记录了152次测量值。使用TCD、ncTCCD和cTCCD测量的平均PSV分别为83±18cm/s、81±19cm/s和93±21cm/s。TCD和ncTCCD之间的PSV无显著差异(偏差=2cm/s,P=1.000),而cTCCD产生的PSV显著高于TCD和ncTCCD(偏差=-10cm/s,P<0.001;偏差=-12cm/s,P≤0.001)。TCD和ncTCCD技术之间的MFV偏差为(偏差=-0.5cm/s;P=1.000),而cTCCD显示出比TCD和ncTCCD更高的MFV(偏差=-8cm/s,P<0.001;偏差=-8cm/s,P≤0.001)。TCCD是一种在评估MCA血流速度方面切实可行的成像技术。cTCCD比非成像TCD和ncTCCD技术更准确,且往往能给出更高的MCA血流速度。ncTCCD与非成像TCD相当,在需要同时使用TCD和TCCD测量的临床病例中应予以考虑。