Indoor carbon dioxide (CO2) concentration has been used as a proxy of the degree of ventilation and, by extension, as an indicator of the risk of contracting respiratory infections. No publications exist regarding indoor air quality (IAQ) parameters of Sri Lankan hospitals.We measured the levels of CO2 and seven other IAQ parameters during morning rush hours for three days, in outpatient departments (OPDs) and emergency treatment units (ETUs) of all 21 teaching hospitals of Sri Lanka. We measured the same parameters of outdoor air also. We calculated the mean values of those parameters. We looked for correlations between outdoors and OPD and ETU levels of selected air quality parameters.The average CO2 levels of outdoors, OPDs and ETUs respectively were 514ppm (ppm = parts per million), 749ppm and 795ppm. The average levels of PM2.5 (particulate matter with diameters <2.5μm) outdoors, OPDs and ETUs respectively, were 28.7μg/m3,32μg/m3 and 25.6 μg/m3. The average levels of PM10 (particulate matter with diameters <10μm) outdoors, OPDs and ETUs respectively, were 49.4μg/m3, 55.5μg/m3 and 47.9 μg/m3. The median levels of formaldehyde outdoors, OPDs and ETUs respectively, were 0.03mg/m3, 0.04mg/m3 and 0.08mg/m3. The median levels of total volatile organic compounds (VOC) outdoors, OPDs and ETUs respectively were 0.12mg/m3, 0.19mg/m3 and 0.38mg/m3.CO2 levels of air in OPDs and ETUs generally were below the national ceilings but above the ceilings used by some developed countries. Outdoors, OPDs and ETUs air contain PM10, PM2.5 levels higher than WHO ceilings, although below the national ceilings. VOC and formaldehyde levels are generally below the national ceilings. Air in OPDs and ETUs is hotter and humid than national ceilings. Outdoor PM10, PM2.5 levels influence OPDs and ETUs levels. We propose methods to reduce the risk of nosocomial respiratory infections and to improve IAQ of Sri Lankan OPDs and ETUs.

摘要

室内二氧化碳(CO₂)浓度已被用作通风程度的替代指标,进而作为感染呼吸道疾病风险的指标。目前尚无关于斯里兰卡医院室内空气质量(IAQ)参数的相关出版物。我们在三天的早高峰时段,对斯里兰卡所有21家教学医院的门诊部(OPD)和急诊治疗单元(ETU)的CO₂水平及其他七个IAQ参数进行了测量。我们还测量了室外空气的相同参数。我们计算了这些参数的平均值。我们研究了室外与OPD及ETU选定空气质量参数水平之间的相关性。室外、OPD和ETU的平均CO₂水平分别为514ppm(ppm = 百万分之一)、749ppm和795ppm。室外、OPD和ETU的PM2.5(直径<2.5μm的颗粒物)平均水平分别为28.7μg/m³、32μg/m³和25.6μg/m³。室外、OPD和ETU的PM10(直径<10μm的颗粒物)平均水平分别为49.4μg/m³、55.5μg/m³和47.9μg/m³。室外、OPD和ETU的甲醛中位数水平分别为0.03mg/m³、0.04mg/m³和0.08mg/m³。室外、OPD和ETU的总挥发性有机化合物(VOC)中位数水平分别为0.12mg/m³、0.19mg/m³和0.38mg/m³。OPD和ETU空气中的CO₂水平总体上低于国家上限,但高于一些发达国家所采用的上限。室外、OPD和ETU空气中的PM10、PM2.5水平高于世界卫生组织的上限,尽管低于国家上限。VOC和甲醛水平总体上低于国家上限。OPD和ETU中的空气比国家上限更热且更潮湿。室外PM10、PM2.5水平会影响OPD和ETU的水平。我们提出了降低医院内呼吸道感染风险以及改善斯里兰卡OPD和ETU室内空气质量的方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f573/10896534/24a780adad9d/pgph.0002862.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验