Suppr超能文献

复合树脂中固化距离对固化深度的影响。

Effect of curing distance for cure depth in composite resin.

作者信息

Malhotra Shantun, Kaur Rubaldeep, Saroa Parneet Kaur, Kaur Kiranjot, Sandhu Komaldeep Kaur, Thukral Vani

机构信息

SGRD Dental College and Hospital, Amritsar, Punjab, India.

出版信息

Bioinformation. 2023 Dec 31;19(13):1353-1358. doi: 10.6026/973206300191353. eCollection 2023.

Abstract

The effect of altering the distance between light tip and outer layer of composite (DLR) on the depth of composite cure with a range of low to high light intensity curing lamps and with different types of light unit is of interest. Three LED units (T= Freelight,U = Ultrablue IS, V = Coltolux LED, one PAC unit (S=PAC) and three halogen light-curing units (P = XL2500, Q = HelioluxVL, R = Visiolux) were analyzed. A human molar tooth that was separated mesio-distally to buccal and lingual halves was used to create a natural tooth sample. Data shows that the depth of cure for the composite material decreased as the distance between the repair and the light source increased. There was no appreciable difference in performance between the LEDs and the other kinds of curing lamps as the distance between them grew.

摘要

改变光尖与复合材料外层之间的距离(DLR)对一系列低到高光照强度固化灯以及不同类型光单元下复合材料的固化深度的影响备受关注。分析了三个发光二极管单元(T = Freelight,U = Ultrablue IS,V = Coltolux LED)、一个等离子弧光固化单元(S = PAC)和三个卤素光固化单元(P = XL2500,Q = HelioluxVL,R = Visiolux)。使用一颗近远中向分离为颊侧和舌侧两半的人类磨牙来制作天然牙齿样本。数据表明,随着修复体与光源之间距离的增加,复合材料的固化深度降低。随着发光二极管与其他类型固化灯之间距离的增加,它们在性能上没有明显差异。

相似文献

1
Effect of curing distance for cure depth in composite resin.
Bioinformation. 2023 Dec 31;19(13):1353-1358. doi: 10.6026/973206300191353. eCollection 2023.
2
Effect of distance from curing light tip to restoration surface on depth of cure of composite resin.
Prim Dent Care. 2008 Oct;15(4):147-52. doi: 10.1308/135576108785891150.
4
Shrinkage behavior of a resin-based composite irradiated with modern curing units.
Dent Mater. 2005 May;21(5):483-9. doi: 10.1016/j.dental.2004.08.007.
5
Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure.
Clin Oral Investig. 2005 Jun;9(2):71-6. doi: 10.1007/s00784-005-0312-9. Epub 2005 Apr 7.
7
Depth of cure and microleakage with high-intensity and ramped resin-based composite curing lights.
J Am Dent Assoc. 2003 Sep;134(9):1215-23. doi: 10.14219/jada.archive.2003.0356.
8
Photoinitiator dependent composite depth of cure and Knoop hardness with halogen and LED light curing units.
Biomaterials. 2003 May;24(10):1787-95. doi: 10.1016/s0142-9612(02)00532-x.

引用本文的文献

1
Depth of Cure of Resin-Based Composites Irradiated With Three Types of Light-Curing Units at Different Output Intensities.
Cureus. 2024 Oct 19;16(10):e71825. doi: 10.7759/cureus.71825. eCollection 2024 Oct.

本文引用的文献

3
Influence of light curing and sample thickness on microhardness of a composite resin.
Clin Cosmet Investig Dent. 2009 May 6;1:21-5. doi: 10.2147/ccide.s4863. Print 2009.
4
A method for improving the light intensity distribution in dental light-curing units.
Dent Mater J. 2011;30(2):151-7. doi: 10.4012/dmj.2010-114. Epub 2011 Mar 4.
5
Current status of visible light activation units and the curing of light-activated resin-based composite materials.
Dent Update. 2010 May;37(4):214-6, 218-20, 223-7. doi: 10.12968/denu.2010.37.4.214.
9
Light-emitting diode curing light irradiance and polymerization of resin-based composite.
J Am Dent Assoc. 2006 Feb;137(2):213-23. doi: 10.14219/jada.archive.2006.0147.
10
Effect of light-tip distance on the shear bond strengths of composite resin.
Angle Orthod. 2005 May;75(3):386-91. doi: 10.1043/0003-3219(2005)75[386:EOLDOT]2.0.CO;2.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验