Suppr超能文献

基于 LC-MS/MS 的唾液中褪黑素、皮质醇和皮质酮同时定量检测方法。

An LC-MS/MS-based method for the simultaneous quantification of melatonin, cortisol and cortisone in saliva.

机构信息

Department of Laboratory Medicine, Netherlands Cancer Institute Amsterdam, the Netherlands.

Department of Laboratory Medicine, Netherlands Cancer Institute Amsterdam, the Netherlands.

出版信息

Anal Biochem. 2024 Jun;689:115496. doi: 10.1016/j.ab.2024.115496. Epub 2024 Mar 1.

Abstract

Disturbances in the diurnal pattern are associated with several clinical and psychological conditions, including depression and fatigue. Salivary sampling for melatonin, cortisol and cortisone provides a non-invasive method for frequent sampling and obtaining biochemical insight into the diurnal pattern of individuals. Therefore, a new liquid chromatography-tandem mass spectrometry-based method for the measurement of salivary melatonin, cortisol and cortisone was developed and validated. The method required 250 μl saliva, used isotope dilution methodology and was based on a liquid-liquid extraction for sample preparation, reversed-phase chromatography and multiple reaction monitoring on a mass spectrometer for quantitation. The lower limits of quantification obtained were 0.010 nmol/L for melatonin, 0.5 nmol/L for cortisol and 1.00 nmol/L for cortisone and the limits of detection were 0.003 nmol/L, 0.15 nmol/L and 0.1 nmol/L respectively. The method imprecision was ≤14% for all measurands, and the method comparison showed highly comparable results with high correlation coefficients (all ≥0.964). Potential interference of cortisol and cortisone by prednisolone was observed and could be detected by chromatogram review. Typical diurnal patterns for melatonin, cortisol and cortisone were observed in the saliva of 20 cancer survivors who collected saliva throughout the day.

摘要

昼夜节律紊乱与多种临床和心理状况有关,包括抑郁和疲劳。唾液采样进行褪黑素、皮质醇和皮质酮的检测为频繁采样提供了一种非侵入性方法,并能深入了解个体的昼夜节律模式的生物化学变化。因此,建立并验证了一种用于测量唾液褪黑素、皮质醇和皮质酮的新型液相色谱-串联质谱法。该方法需要 250μl 唾液,采用同位素稀释法,基于液液萃取进行样品前处理,反相色谱和质谱多重反应监测进行定量分析。获得的最低定量下限分别为褪黑素 0.010nmol/L、皮质醇 0.5nmol/L 和皮质酮 1.00nmol/L,检测限分别为 0.003nmol/L、0.15nmol/L 和 0.10nmol/L。对于所有测定物,该方法的精密度均≤14%,方法比较显示具有高度可比性,相关系数均≥0.964。观察到泼尼松龙对皮质醇和皮质酮的潜在干扰,可通过色谱图审查检测到。20 名癌症幸存者全天采集唾液,观察到了唾液中褪黑素、皮质醇和皮质酮的典型昼夜节律模式。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验