Suppr超能文献

非激素宫内节育器致月经过多女性中超声、宫腔镜检查与细胞因子之间的矛盾性研究:一项前瞻性研究

The contradictive findings between ultrasound, hysteroscopy and cytokines in women with nonhormonal IUDs suffering from menorrhagia: a prospective study.

作者信息

Watad Hadel, Ifrach Udi, Stockheim David, Yulzari Vered, Meron Orly C, Blank Miri, Sredni Benjamin, Weisz Boaz, Cohen Shlomo B

机构信息

Department of Obstetrics and Gynecology, Chaim Sheba Medical Center, Tel-Hashomer, Israel.

School of Medicine, Tel Aviv University, Tel Aviv, Israel.

出版信息

Arch Gynecol Obstet. 2024 May;309(5):2057-2062. doi: 10.1007/s00404-024-07457-7. Epub 2024 Mar 16.

Abstract

PURPOSE

The objective of this study is to assess the correlation between bleeding irregularities and the accurate placement of the intrauterine device (IUD) device in the uterine cavity, determined through transvaginal ultrasonography and hysteroscopy. In addition, the study aims to examine the cytokine profile in the uterine cavity and serum of patients experiencing bleeding irregularities after the insertion of nonhormonal IUDs.

METHODS

A prospective cohort study was conducted at a single tertiary medical center, wherein patients experiencing intermenstrual bleeding and spotting after the insertion of nonhormonal IUDs were enrolled. The study involved hysteroscopic and sonographic assessments of the uterine cavity and IUD placement, along with the analysis of blood and uterine cavity cytokine profiles.

RESULTS

During the period between July 2019 and February 2020, a total of eight patients who experienced intermenstrual bleeding and spotting after the insertion of nonhormonal IUDs were enrolled the study. One case was excluded since a progestative device was detected by ultrasound. Out of the five cases that underwent a thorough ultrasonographic assessment, three cases (60%) showed an embedded IUD. However, these findings were excluded by the hysteroscopic evaluation.

CONCLUSION

The results suggest that ultrasonographic assessment may lead to an overdiagnosis of IUD mispositioning compared to hysteroscopy. In addition, both ultrasound and hysteroscopy have limitations in diagnosing the cause of bleeding in most cases. The role of local reactive inflammatory cytokines should be further studied.

摘要

目的

本研究的目的是通过经阴道超声检查和宫腔镜检查,评估出血异常与宫腔内宫内节育器(IUD)准确放置之间的相关性。此外,该研究旨在检查放置非激素IUD后出现出血异常的患者宫腔和血清中的细胞因子谱。

方法

在一家三级医疗中心进行了一项前瞻性队列研究,纳入了放置非激素IUD后出现经间期出血和点滴出血的患者。该研究包括对宫腔和IUD放置进行宫腔镜和超声评估,以及分析血液和宫腔细胞因子谱。

结果

在2019年7月至2020年2月期间,共有8例放置非激素IUD后出现经间期出血和点滴出血的患者纳入研究。1例因超声检测到孕激素装置而被排除。在接受全面超声评估的5例病例中,3例(60%)显示IUD嵌入。然而,这些发现被宫腔镜评估排除。

结论

结果表明,与宫腔镜检查相比,超声评估可能导致IUD位置异常的过度诊断。此外,在大多数情况下,超声和宫腔镜检查在诊断出血原因方面都有局限性。局部反应性炎症细胞因子的作用应进一步研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b9e3/11018669/1f31c6841cd4/404_2024_7457_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验