Suppr超能文献

手术室中的分贝:外科手术期间噪音水平的研究。

Decibels in the operating theatre: a study of noise levels during surgical procedures.

作者信息

Au Joanne, Hamilton Sam, Webb Angela

机构信息

Plastic and Reconstructive Surgery, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.

出版信息

ANZ J Surg. 2024 Oct;94(10):1841-1845. doi: 10.1111/ans.19001. Epub 2024 Mar 30.

Abstract

BACKGROUND

Exposure to excessive noise volumes is an occupational health and safety risk. Australian guidelines recommend a time weighted exposure maximum of 85 dB (dB) or a maximum peak noise level of up to 140 dB, as chronic and repeated high dB exposure can result in significant hearing impairment. The aim of this study was to assess the volume of noise generated by common surgical instruments while utilizing the National Institute for Occupational Safety and Health (NIOSH) app.

METHODS

Sound levels were measured using the NIOSH app. The NIOSH app was used to take equivalent continuous A-weighted sound levels (L) and the C-weighted peak sound pressure (L) measurements for specific instruments while in use in theatre. A minimum of three readings per instrument were taken at immediate and working distances.

RESULTS

L measurements ranged from 62.9 to 89.3 dB. The Padgett Dermatome and Frazier Sucker exceeded recommended exposure limits with an averaged L reading of 85.7 dB(A) and 85.1 dB(A) respectively. L readings ranged from 89.9 to 114.7 dB(C) with none of the instruments exceeding a peak sound level beyond the recommended level of 140 dB(C).

CONCLUSION

The cumulative effect of loud surgical instruments across prolonged or combined operations may result in theatre staff being exposed to hazardous noise levels, impacting the health and wellbeing of staff, staff performance and patient care. Utilization of a phone app can improve the awareness of noise pollution in theatres, thereby empowering staff to be proactive about their health and improvement of their work environment.

摘要

背景

暴露于过高音量的噪声是一种职业健康与安全风险。澳大利亚指南建议时间加权暴露最大值为85分贝(dB)或最大峰值噪声水平高达140dB,因为长期和反复的高dB暴露会导致严重的听力损伤。本研究的目的是利用美国国家职业安全与健康研究所(NIOSH)应用程序评估常见手术器械产生的噪声音量。

方法

使用NIOSH应用程序测量声级。NIOSH应用程序用于在手术室使用特定器械时测量等效连续A加权声级(L)和C加权峰值声压(L)。每种器械在近距离和工作距离至少进行三次读数。

结果

L测量值范围为62.9至89.3dB。帕吉特皮肤刀和弗雷泽吸引器超过了推荐暴露限值,平均L读数分别为85.7dB(A)和85.1dB(A)。L读数范围为89.9至114.7dB(C),没有器械的峰值声级超过推荐的140dB(C)水平。

结论

在长时间或联合手术中,响亮的手术器械的累积效应可能导致手术室工作人员暴露于有害噪声水平,影响工作人员的健康和福祉、工作表现及患者护理。使用手机应用程序可以提高对手术室噪声污染的认识,从而使工作人员积极关注自身健康并改善工作环境。