Abstract

This study was initiated to investigate noise levels in general pediatric facilities. Although occupational noise limits of 85dBA for LAeq,8h (daily noise exposure) and 140dBC for LCpeak (peak sound level) have proven to prevent hearing loss, even low levels of continuous noise (45dBA and above) can cause adverse health effects (ISO = International Organization for Standardization, A = Austrian VOLV). The sound level measurements of LAeq (equivalent sound level) and LCpeak were conducted with a decibel meter in the examination rooms (EXR) and waiting rooms (WR) of 10 general pediatric practices and outpatient clinics in the city of Vienna, Austria. LAeq,8h was calculated from LAeq, and independent variables with a potential influence on noise levels were also examined. In EXR, the random sample consisted of 5 to 11 measuring periods per facility (mean: 7.1 ± 1.9) with a total duration between 43.85 and 98.45 min. (total: 10:19:04). With LAeq ranging from 67.2 to 80.2dBA, specific recommended limits were exceeded considerably (ISO: 45dBA; A: 50dBA). In WR, the random sample comprised 5 to 18 measurements per facility (mean: 13.7 ± 5.0) with a total duration ranging from 25 to 90 min. (total: 11:25:00). The values for LAeq were between 60.6dBA and 67.0dBA. All of these significantly exceeded recommended limits of 55dBA (ISO) and 5 out of 10 exceeded 65dBA (A). LCpeak reached 116.1dBC in WR and 114.1dBC in EXR. The highest calculated daily noise exposure of pediatricians (LAeq,8h) was 79dBA. Although no significantly increased risk for hearing loss can be concluded from our findings, it must be assumed that noise levels in general pediatrics have the potential to cause stress and associated health issues. Further research is necessary to foster the recognition of noise-related health impairments of pediatric staff as occupational diseases.

摘要

这项研究旨在调查一般儿科设施中的噪音水平。尽管职业噪声限值为 LAeq,8h(每日噪声暴露)85dBA 和 LCpeak(峰值声级)140dBC 已被证明可预防听力损失,但即使是低水平的连续噪声(45dBA 及以上)也会对健康产生不利影响(ISO = 国际标准化组织,A = 奥地利 VOLV)。在维也纳市的 10 家普通儿科诊所和门诊中,使用分贝计在检查室(EXR)和候诊室(WR)测量 LAeq(等效声级)和 LCpeak。LAeq,8h 是从 LAeq 计算得出的,还检查了对噪声水平有潜在影响的独立变量。在 EXR 中,随机样本由每个设施的 5 到 11 个测量时段组成(平均值:7.1 ± 1.9),总持续时间为 43.85 到 98.45 分钟。(总时间:10:19:04)。LAeq 的范围为 67.2 到 80.2dBA,大大超过了特定的建议限值(ISO:45dBA;A:50dBA)。在 WR 中,随机样本由每个设施的 5 到 18 个测量组成(平均值:13.7 ± 5.0),总持续时间从 25 到 90 分钟不等。(总时间:11:25:00)。LAeq 的值在 60.6dBA 和 67.0dBA 之间。所有这些都明显超过了 55dBA(ISO)和 10 个中的 5 个超过 65dBA(A)的建议限值。WR 中的 LCpeak 达到 116.1dBC,EXR 中的 LCpeak 达到 114.1dBC。儿科医生计算的最高日噪声暴露量(LAeq,8h)为 79dBA。尽管我们的研究结果不能得出听力损失风险显著增加的结论,但必须假设一般儿科的噪声水平有可能造成压力和相关的健康问题。需要进一步研究以提高对儿科工作人员与噪声有关的健康损害的认识,将其视为职业病。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d95b/6415854/abd9fbb80295/pone.0213722.g002.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验