Schweer H, Kammer J, Seyberth H W
J Chromatogr. 1985 Mar 22;338(2):273-80. doi: 10.1016/0378-4347(85)80098-0.
A method for simultaneous determination of prostaglandin E2 (PGE2), prostaglandin F2 alpha (PGF2 alpha), 6-keto-prostaglandin F1 alpha (6-keto-PGF1 alpha), and thromboxane B2 (TxB2) in plasma was developed. After acidification and addition of 2H- and 3H-labelled internal standards, plasma prostanoids were extracted by reversed-phase cartridges and purified by normal-phase high-performance liquid chromatography. The pentafluorobenzyl, methoxime, trimethylsilyl derivatives were formed. Negative-ion chemical-ionization mass spectra with methane as reagent gas show one intense peak at m/z (M - pentafluorobenzyl). This ion was used for selective-ion monitoring. Prostanoid plasma concentrations (pg/ml) in five healthy volunteers were: PGE2 2.0-10.4, PGF2 alpha 2.2-9.8, 6-keto-PGF1 alpha 0.6-1.8, and TxB2 3.0-45.3. However, there is evidence that the TxB2 values may frequently be falsely high because of ex vivo production during the sampling procedure.
建立了一种同时测定血浆中前列腺素E2(PGE2)、前列腺素F2α(PGF2α)、6-酮-前列腺素F1α(6-酮-PGF1α)和血栓素B2(TxB2)的方法。在酸化并加入2H和3H标记的内标后,血浆前列腺素通过反相柱提取,并用正相高效液相色谱法纯化。形成五氟苄基、甲氧肟、三甲基硅烷基衍生物。以甲烷作为反应气的负离子化学电离质谱在m/z(M - 五氟苄基)处显示一个强峰。该离子用于选择性离子监测。五名健康志愿者的前列腺素血浆浓度(pg/ml)为:PGE2 2.0 - 10.4,PGF2α 2.2 - 9.8,6-酮-PGF1α 0.6 - 1.8,TxB2 3.0 - 45.3。然而,有证据表明,由于采样过程中的体外产生,TxB2值可能经常被错误地高估。