Suppr超能文献

评价可膨胀楔形锁定钉逆行固定的力学行为:有限元研究。

Evaluation of the mechanical behaviour of the expandable wedge locked nail fixation in retrograde use: A finite element study.

机构信息

Department of Mechanical Engineering, KTO Karatay University, 42020, Konya, Turkey.

Department of Mechanical Engineering, TOBB University of Economics and Technology, 06560, Ankara, Turkey.

出版信息

Comput Biol Med. 2024 May;174:108419. doi: 10.1016/j.compbiomed.2024.108419. Epub 2024 Apr 5.

Abstract

INTRODUCTION

In literature, there have been many studies conducted to research the alternatives of standard interlocking intramedullary nailing. The expandable wedge locked nail fixation, which is thought as a new alternative to the standard interlocking nailing, has been presented in previous numerical studies. The antegrade usage of the wedge locked nail fixation has provided promising results. From this point, the aim of the study is to evaluate mechanical behavior of its retrograde usage on femur models. Additionally, another aim of the study is to investigate the effect of fracture level on mechanical properties of the fixation.

MATERIALS AND METHODS

The mechanical behaviors of the wedge locked nail and standard interlocking nail fixations were compared by finite element methods. Sawbones femurs having osteotomies at five different levels to simulate different fractures were fixed with wedge locked nail or interlocking nail by using retrograde approach. With respect to the fracture level, two different nail lengths were used. Axial compression load was applied to fixations. The mechanical behaviors of the fixations were evaluated with respect to stiffness of the fixations and stresses occurred on both implants and bones.

RESULTS

Any of the wedge locked nail fixation did not slip at canal. The stress and stiffness results were mostly close with each other for both nail types. The maximum stresses at locking elements or bones contacting these elements increased with decreased distance between the fracture and relevant locking elements.

DISCUSSION

The wedge locked nail fixation showed comparable results to the standard interlocking nail fixation with respect to the stiffness and stress. Under axial loading, wedge locked nail provided a secured fixation without any slippage and preserved its position inside the medullary canal. It may be thought as a safe alternative to the standard interlocking nail fixation for retrograde usage. Additionally, according to stress results, it is advised to the surgeons to avoid a close locking to the fracture line.

摘要

简介

在文献中,已经有许多研究致力于探索标准交锁髓内钉的替代方案。可扩张楔形锁定钉固定被认为是标准交锁钉的一种新的替代方案,已经在之前的数值研究中提出。楔形锁定钉固定的顺行使用已经取得了有希望的结果。从这一点出发,本研究的目的是评估其逆行使用在股骨模型中的力学行为。此外,本研究的另一个目的是研究骨折部位对固定力学性能的影响。

材料和方法

通过有限元方法比较了楔形锁定钉和标准交锁钉固定的力学行为。使用逆行方法,使用楔形锁定钉或交锁钉固定具有五种不同水平截骨的模拟不同骨折的锯骨股骨。考虑到骨折部位,使用了两种不同的钉长。对固定装置施加轴向压缩载荷。根据固定装置的刚度和两个植入物和骨骼上的应力来评估固定装置的力学行为。

结果

任何楔形锁定钉固定都不会在管内滑动。两种钉类型的刚度和应力结果都非常接近。锁定元件或与这些元件接触的骨骼上的最大应力随着骨折与相关锁定元件之间的距离减小而增加。

讨论

与标准交锁钉固定相比,楔形锁定钉固定在刚度和应力方面表现出相似的结果。在轴向加载下,楔形锁定钉固定提供了安全的固定,没有任何滑动,并保持其在髓内管内的位置。对于逆行使用,它可以被认为是标准交锁钉固定的一种安全替代方案。此外,根据应力结果,建议外科医生避免与骨折线紧密锁定。