Suppr超能文献

小儿膝关节髌骨高度测量的可靠性及形态学分析

Reliability and modality analysis of patellar height measurement in pediatric knee.

作者信息

Kwak Yoon Hae, Park Soo-Sung, Huser Aaron J, Kim Keunho, Koh Yong-Gon, Nam Ji-Hoon, Kang Kyoung-Tak

机构信息

Department of Orthopedic Surgery, Asan Medical Center Children's Hospital, University of Ulsan College of Medicine, Seoul, Republic of Korea.

Department of Orthopedic Surgery, Paley Advanced Limb Lengthening Institute, St. Mary's Hospital, West Palm Beach, FL, United States.

出版信息

Front Pediatr. 2024 Mar 26;12:1323015. doi: 10.3389/fped.2024.1323015. eCollection 2024.

Abstract

INTRODUCTION

Various measurement methods and imaging technique are in use to measure patellar height in pediatric patients. However, there is no gold standard as to which measurement method and modality are the most reliable for pediatric patients. Therefore, the aim of this study was to determine the inter-observer reliability, intra-observer reliability, and applicability of various patellar height measurement methods in pediatric knee. Additionaly, we analyzed the reliability across different imaging modalities.

METHODS

Total 450 pediatric patients (age: 5-18 years) were evaluated using lateral knee radiographs and magnetic resonance imaging (MRI). The patellar height ratios were measured using five methods. Five methods were Insall-Salvati (IS), Koshino-Sugimoto (KS), Blackburne-Peel (BP), modified Insall-Salvati (MIS), and Caton-Deschamps (CD). The patients were categorized into two age groups: P (ages 5-13) and Q (ages 14-18). Each measurement was conducted twice by two raters. The intra-observer reliability, inter-observer reliability and inter-modality reliability were calculated. In addition, applicability was defined as the possibility to apply each measurement method to each age group.

RESULTS

The KS method showed the highest inter-observer reliability and intra-observer reliability when using MRI for both age groups. The inter-observer reliability and intra-observer reliability of the IS for lateral knee radiographs was highest among all observers for group Q. The CD method showed the highest inter-observer reliability in group P, while the KS showed the highest intra-observer reliability in group P using lateral radiographs. The KS method showed the highest inter-modality reliability in group P, while the IS showed the highest inter-modality reliability in group Q. The KS method was applicable to all patients when using lateral knee radiography, and the IS method was applicable to all patients when using MRI.

CONCLUSIONS

Our results show that the reliability of various measurement method and imaging technique differed based on pediatric knee age group when measuring patellar height. Therefore, in the case of pediatric patients, reliability measurement methods and imaging techniques according to the patient's age should be applied.

摘要

引言

目前有多种测量方法和成像技术用于测量儿科患者的髌骨高度。然而,对于儿科患者而言,哪种测量方法和方式最为可靠尚无金标准。因此,本研究的目的是确定各种髌骨高度测量方法在儿科膝关节中的观察者间可靠性、观察者内可靠性及适用性。此外,我们还分析了不同成像方式之间的可靠性。

方法

共对450例儿科患者(年龄5 - 18岁)进行了膝关节侧位X线片和磁共振成像(MRI)评估。采用五种方法测量髌骨高度比值。这五种方法分别是Insall - Salvati(IS)法、小杉 - 杉本(Koshino - Sugimoto,KS)法、布莱克本 - 皮尔(Blackburne - Peel,BP)法、改良Insall - Salvati(modified Insall - Salvati,MIS)法和卡顿 - 德尚(Caton - Deschamps,CD)法。患者被分为两个年龄组:P组(5 - 13岁)和Q组(14 - 18岁)。每项测量均由两名评估者进行两次。计算观察者内可靠性、观察者间可靠性和不同成像方式间的可靠性。此外,适用性定义为每种测量方法应用于每个年龄组的可能性。

结果

对于两个年龄组,在使用MRI时,KS法显示出最高 的观察者间可靠性和观察者内可靠性。对于Q组,在所有观察者中,膝关节侧位X线片的IS法的观察者间可靠性和观察者内可靠性最高。CD法在P组中显示出最高的观察者间可靠性,而在P组中使用侧位X线片时,KS法显示出最高的观察者内可靠性。在P组中,KS法显示出最高的不同成像方式间可靠性,而在Q组中,IS法显示出最高的不同成像方式间可靠性。当使用膝关节侧位X线片时,KS法适用于所有患者;当使用MRI时,IS法适用于所有患者。

结论

我们的结果表明,在测量儿科患者髌骨高度时,各种测量方法和成像技术的可靠性因儿科膝关节年龄组而异。因此,对于儿科患者,应根据患者年龄应用可靠的测量方法和成像技术。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/47aa/11002117/7c1015ba797f/fped-12-1323015-g001.jpg