Aarthi S, Sivakumar J S, Sivakumar A Andamuthu, Soundappan J Saravanapriyan, Chittrarasu M, Jayanthi G
Department of Conservative Dentistry, Vivekanandha Dental College for Women, Namakkal, Tamil Nadu, India.
J Conserv Dent Endod. 2024 Mar;27(3):262-267. doi: 10.4103/JCDE.JCDE_266_23. Epub 2024 Mar 6.
Safe and efficient removal of all root filling materials from the root canal system without compromising radicular dentin structure is essential for optimal nonsurgical retreatment.
The aim of this study was to evaluate and compare the incidence of dentinal defects caused during root canal filling removal using conventional, rotary, and reciprocating retreatment file systems.
A detailed protocol explaining purpose and procedures of the study was submitted to the Institutional Ethics Committee and ethical clearance obtained.
Sixty human maxillary permanent central incisors were collected and decoronated to 12-mm standardized length. The canals prepared up to a master apical file size F3 with Protaper hand files, obturated using AH plus sealer, examined under the stereomicroscope (×40 magnification): Group I: Control ( = 15), Group II: Conventional ( = 15), Group III: Protaper Universal Retreatment Files ( = 15), and Group IV: Reciproc Blue ( = 15). After instrumentation, teeth were sectioned at 3, 6, and 9 mm from the apex to evaluate the presence of dentinal defects under the stereomicroscope.
Statistics were performed using the SPSS, version, 25 (SPSS Inc., Chicago, IL, USA). Initially, normality test was done using the Shapiro-Wilk test and data were not normally distributed followed by Kruskal-Wallis test. P < 0.05 is considered statistically significant.
Maximum percentage increase in dentinal defects was observed in Protaper Universal Retreatment Files followed by Conventional method and Reciproc Blue.
Significantly Reciproc Blue reduced the incidence of dentinal defects after root canal preparation.
在不损害根管牙本质结构的前提下,安全有效地从根管系统中去除所有根管充填材料对于最佳的非手术再治疗至关重要。
本研究的目的是评估和比较使用传统、旋转和往复式再治疗锉系统在去除根管充填物过程中引起的牙本质缺陷的发生率。
一份详细解释研究目的和程序的方案已提交给机构伦理委员会并获得伦理批准。
收集60颗人类上颌恒中切牙,并将其冠部截除至12毫米的标准长度。使用Protaper手动锉将根管预备至主尖锉F3大小,用AH plus封闭剂充填,在体视显微镜(×40放大倍数)下检查:第一组:对照组(n = 15),第二组:传统组(n = 15),第三组:Protaper通用再治疗锉组(n = 15),第四组:Reciproc Blue组(n = 15)。器械操作后,将牙齿从根尖分别在3毫米、6毫米和9毫米处切片,在体视显微镜下评估牙本质缺陷的存在情况。
使用SPSS 25版软件(SPSS公司,美国伊利诺伊州芝加哥)进行统计分析。首先,使用Shapiro-Wilk检验进行正态性检验,数据呈非正态分布,随后进行Kruskal-Wallis检验。P < 0.05被认为具有统计学意义。
在Protaper通用再治疗锉组中观察到牙本质缺陷的最大百分比增加,其次是传统方法组和Reciproc Blue组。
Reciproc Blue显著降低了根管预备后牙本质缺陷的发生率。