Suppr超能文献

应用手动、旋转和往复器械预备直和弯曲根管后牙本质微裂纹形成的 micro-computed 断层扫描评估。

Micro-computed tomographic assessment of dentinal microcrack formation in straight and curved root canals in extracted teeth prepared with hand, rotary and reciprocating instruments.

机构信息

Department of Prosthodontics and Oral and Maxillofacial Surgery, Dental School, Recife, PE, Brazil.

Department of Nuclear Energy, Federal University of Pernambuco, Recife, PE, Brazil.

出版信息

Int Endod J. 2021 Aug;54(8):1362-1368. doi: 10.1111/iej.13521. Epub 2021 Apr 25.

Abstract

AIM

To compare microcrack formation in roots of extracted teeth after the shaping of straight and curved root canals with hand, rotary and reciprocating files using micro-computed tomographic (micro-CT) analysis.

METHODOLOGY

Thirty straight mandibular incisors and 30 severely curved mesial roots of mandibular molars were randomly divided into 6 experimental groups (n = 10) according to the systems used for the root canal preparation and the root canal curvature: ProTaper Universal for Hand Use (Dentsply Sirona, Ballaigues, Switzerland), HyFlex EDM (Coltene-Whaledent, Altstätten, Switzerland) and Reciproc Blue (VDW, Munich, Germany) files used in mandibular incisors (straight canals) and mesial roots of mandibular molars (curved canals). The roots were imaged with micro-CT scanning at an isotropic resolution of 14 μm before and after root canal preparation, and the cross-sectional images generated were assessed to detect microcracks.

RESULTS

All dentinal defects identified after root canal preparation were already present before instrumentation, and no new microcracks were detected. Dentinal microcracks were present in 19% (ProTaper Universal for Hand Use), 11% (Hyflex EDM) and 23% (Reciproc Blue) of the cross-sections when the instrumentation was performed in mandibular incisors. Instrumentation of mandibular molars revealed microcracks in 15% (ProTaper Universal for Hand Use), 16% (Hyflex EDM) and 17% (Reciproc Blue) of the cross-sections.

CONCLUSIONS

Preparation of straight and curved root canals with ProTaper Universal for Hand Use, HyFlex EDM and Reciproc Blue systems did not produce microcracks in extracted teeth when evaluated with micro-CT.

摘要

目的

使用微计算机断层扫描(micro-CT)分析比较手动、旋转和往复锉在直弯根管成形后对离体牙牙根微裂纹形成的影响。

方法

将 30 颗直的下颌切牙和 30 颗严重弯曲的下颌磨牙近中根随机分为 6 个实验组(n=10),根据根管预备系统和根管弯曲程度进行分组:ProTaper Universal 手动(登士柏西诺德,Ballaigues,瑞士)、HyFlex EDM(登士柏威伐,Altstätten,瑞士)和 Reciproc Blue(VDW,慕尼黑,德国)锉用于下颌切牙(直根管)和下颌磨牙近中根(弯曲根管)。根管预备前后对牙根进行 micro-CT 扫描,以 14μm 的各向同性分辨率成像,评估生成的横截面图像以检测微裂纹。

结果

根管预备后发现的所有牙本质缺陷在器械预备前已经存在,没有发现新的微裂纹。在进行下颌切牙根管预备时,ProTaper Universal 手动、HyFlex EDM 和 Reciproc Blue 系统分别有 19%、11%和 23%的横截面存在牙本质微裂纹。在进行下颌磨牙根管预备时,ProTaper Universal 手动、HyFlex EDM 和 Reciproc Blue 系统分别有 15%、16%和 17%的横截面存在微裂纹。

结论

使用 ProTaper Universal 手动、HyFlex EDM 和 Reciproc Blue 系统预备直弯根管时,使用 micro-CT 评估离体牙时不会产生微裂纹。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验