使用改良被动泄气式封管注射针评估单牙胶尖根管充填质量的微计算机断层扫描:一项体外研究。

Micro-computed tomographic evaluation on the quality of single-cone obturation using a modified passive-deflation sealer injection needle: an in vitro study.

机构信息

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, People's Republic of China.

出版信息

BMC Oral Health. 2024 Apr 20;24(1):476. doi: 10.1186/s12903-024-04232-7.

Abstract

OBJECTIVES

This study aimed to design a modified passive-deflation sealer injection needle and investigate its ability to improve obturation quality of single-cone technique through assessing the distribution of voids in root canals using micro-computed tomography (micro-CT).

MATERIALS AND METHODS

Forty-eight mandibular incisors were divided into eight groups (n = 6), according to the taper of root canal preparation (0.06 or 0.04), the needle used for sealer injection (modified or commercial iRoot SP injection needle), and the obturation method (iRoot SP sealer-only or single-cone obturation). After obturation, each specimen was scanned by micro-CT. The volumetric percentage and distribution of all voids were first analyzed and compared among groups, then the open and closed voids were separately analyzed and compared among single-cone obturation groups.

RESULTS

Compared to commercial needle groups, modified needle groups showed much less voids, especially in the apical root canal part (P < 0.05). Besides, the modified needle groups produced much less open voids than commercial needle groups despite the root canal taper (P < 0.05).

CONCLUSIONS

The modified passive deflation sealer injection needle could effectively improve the quality of single-cone obturation through reducing intra-canal voids, especially open voids throughout the root canal, thus might possibly be developed as an effective intra-canal sealer delivering instrument.

摘要

目的

本研究旨在设计一种改良的被动泄气式封闭剂注射针,并通过微计算机断层扫描(micro-CT)评估根管内空隙的分布来研究其对单根管技术封闭质量的改善作用。

材料与方法

48 颗下颌切牙根据根管预备锥度(0.06 或 0.04)、用于封闭剂注射的针(改良或商业 iRoot SP 注射针)以及封闭方法(iRoot SP 封闭剂单独或单根管封闭)分为 8 组(n=6)。封闭后,每个标本均通过 micro-CT 扫描。首先分析和比较各组之间所有空隙的体积百分比和分布,然后单独分析和比较单根管封闭组中的开放和封闭空隙。

结果

与商业用针组相比,改良用针组的空隙明显较少,尤其是根尖根管部分(P<0.05)。此外,改良用针组产生的开放空隙明显少于商业用针组,而与根管锥度无关(P<0.05)。

结论

改良的被动泄气式封闭剂注射针可以通过减少根管内的空隙,尤其是整个根管内的开放空隙,有效改善单根管封闭的质量,因此可能开发为一种有效的根管内封闭剂输送器械。