Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China.
Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China.
J Prosthodont Res. 2024 Oct 16;68(4):658-666. doi: 10.2186/jpr.JPR_D_23_00278. Epub 2024 Apr 19.
Based on a self-controlled case, this study evaluated the finite element analysis (FEA) results of a single missing molar with wide mesiodistal length (MDL) restored by a single or double implant-supported crown.
A case of a missing bilateral mandibular first molar with wide MDL was restored using a single or double implant-supported crown. The implant survival and peri-implant bone were compared. FEA was conducted in coordination with the case using eight models with different MDLs (12, 13, 14, and 15 mm). Von Mises stress was calculated in the FEA to evaluate the biomechanical responses of the implants under increasing vertical and lateral loading, including the stress values of the implant, abutment, screw, crown, and cortical bone.
The restorations on the left and right sides supported by double implants have been used for 6 and 12 years, respectively, and so far have shown excellent osseointegration radiographically.The von Mises stress calculated in the FEA showed that when the MDL was >14 mm, both the bone and prosthetic components bore more stress in the single implant-supported strategy. The strength was 188.62-201.37 MPa and 201.85-215.9 MPa when the MDL was 14 mm and 15 mm, respectively, which significantly exceeded the allowable yield stress (180 MPa).
Compared with the single implant-supported crown, the double implant-supported crown reduced peri-implant bone stress and produced a more appropriate stress transfer model at the implant-bone interface when the MDL of the single missing molar was ≥14 mm.
本研究通过单病例自身对照,评估了单个远中宽度较大(MDL)缺失磨牙用单个或两个种植体支持的牙冠修复的有限元分析(FEA)结果。
采用单个或两个种植体支持的牙冠修复双侧下颌第一磨牙缺失且 MDL 较宽的病例。比较了种植体的存活率和种植体周围骨情况。使用 8 个 MDL(12、13、14 和 15mm)不同的模型与病例相协调进行 FEA。在 FEA 中计算 Von Mises 应力以评估在垂直和侧向加载增加时种植体的生物力学反应,包括种植体、基台、螺钉、牙冠和皮质骨的应力值。
双侧植入物支持的修复体分别使用了 6 年和 12 年,目前显示出良好的影像学骨整合。FEA 中计算的 Von Mises 应力表明,当 MDL>14mm 时,单个种植体支持策略中,骨和修复体组件承受的应力更大。当 MDL 为 14mm 和 15mm 时,强度分别为 188.62-201.37MPa 和 201.85-215.9MPa,明显超过允许的屈服应力(180MPa)。
与单个种植体支持的牙冠相比,当单个缺失磨牙的 MDL≥14mm 时,双种植体支持的牙冠减少了种植体周围骨的应力,并在种植体-骨界面产生了更合适的应力传递模型。