Suppr超能文献

低级别胶质瘤保头皮的先进放疗技术的剂量学比较

Dosimetric comparison of advanced radiation techniques for scalp-sparing in low-grade gliomas.

作者信息

Yu Hang, He Shuangshuang, He Yisong, Dai Guyu, Fu Yuchuan, Zeng Xianhu, Liu Mengyuan, Ai Ping

机构信息

Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, 610041, Chengdu, Sichuan Province, China.

Department of Radiation Oncology and Department of Head and Neck Oncology, Cancer Center, West China Hospital, Sichuan University, Sichuan, China.

出版信息

Strahlenther Onkol. 2024 Sep;200(9):785-796. doi: 10.1007/s00066-024-02229-3. Epub 2024 Apr 22.

Abstract

BACKGROUND

Alopecia causes significant distress for patients and negatively impacts quality of life for low-grade glioma (LGG) patients. We aimed to compare and evaluate variations in dose distribution for scalp-sparing in LGG patients with proton therapy and photon therapy, namely intensity-modulated proton therapy (IMPT), intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT).

METHODS

This retrospective study utilized a dataset comprising imaging data from 22 patients with LGG who underwent postoperative radiotherapy. Treatment plans were generated for each patient with scalp-optimized (SO) approaches and scalp-non-optimized (SNO) approaches using proton techniques and photons techniques; all plans adhered to the same dose constraint of delivering a total radiation dose of 54.04 Gy to the target volume. All treatment plans were subsequently analyzed.

RESULTS

All the plans generated in this study met the dose constraints for the target volume and OARs. The SO plans resulted in reduced maximum scalp dose (D), mean scalp dose (D), and volume of the scalp receiving 30 Gy (V) and 40 Gy (V) compared with SNO plans in all radiation techniques. Among all radiation techniques, the IMPT plans exhibited superior performance compared to other plans for dose homogeneity as for SO plans. Also, IMPT showed lower values for D and D than all photon radiation techniques.

CONCLUSION

Our study provides evidence that the SO approach is a feasible technique for reducing scalp radiation dose. However, it is imperative to conduct prospective trials to assess the benefits associated with this approach.

摘要

背景

脱发给患者带来极大困扰,并对低级别胶质瘤(LGG)患者的生活质量产生负面影响。我们旨在比较和评估质子治疗与光子治疗(即调强质子治疗(IMPT)、调强放射治疗(IMRT)、容积调强弧形治疗(VMAT)和螺旋断层放射治疗(HT))在LGG患者中进行头皮 sparing时剂量分布的差异。

方法

这项回顾性研究使用了一个数据集,该数据集包含22例接受术后放疗的LGG患者的影像数据。使用质子技术和光子技术,为每位患者生成了头皮优化(SO)方法和非头皮优化(SNO)方法的治疗计划;所有计划均遵循向靶区输送54.04 Gy总辐射剂量的相同剂量约束。随后对所有治疗计划进行了分析。

结果

本研究中生成的所有计划均满足靶区和危及器官的剂量约束。与所有放射技术中的SNO计划相比,SO计划导致最大头皮剂量(D)、平均头皮剂量(D)以及接受30 Gy(V)和40 Gy(V)的头皮体积降低。在所有放射技术中,对于SO计划,IMPT计划在剂量均匀性方面表现优于其他计划。此外,IMPT的D和D值低于所有光子放射技术。

结论

我们的研究提供了证据,表明SO方法是一种降低头皮辐射剂量的可行技术。然而,必须进行前瞻性试验以评估与该方法相关的益处。