Suppr超能文献

测量技术的选择是否会影响氧化锆和钴铬合金修复体之间的拟合比较?

Does the choice of the measuring technique affect the comparison of fit between zirconia and cobalt-chromium prostheses?

机构信息

Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon.

Department of Fixed Prosthodontics, Faculty of Dentistry, Saint Joseph University, Beirut, Lebanon.

出版信息

J Indian Prosthodont Soc. 2024 Apr 1;24(2):201-207. doi: 10.4103/jips.jips_429_23. Epub 2024 Apr 23.

Abstract

AIMS

The objectives of the study were to compare the adaptation of presintered zirconia and cobalt- chromium prostheses using microcomputed tomography (μCT), scanning electron microscopy (SEM), and stereomicroscope (SM).

MATERIALS AND METHODS

Twenty-four fixed dental prostheses (FDPs) were fabricated on metal abutments, duplicated from maxillary first premolar and first molar prepared on a typodont model. Teeth were reduced to obtain chamfer of 1.2 mm and reduction occlusaly of 2 mm occlusal. Scanning of the abutments was done with random assignment to two groups receiving the FDPs made from soft-milled Co-Cr (n = 12) and zirconia (n = 12). Marginal and internal gaps were assessed using three evaluation techniques (X-ray microcomputer tomography, SEM, and stereomicroscopy).

STATISTICAL ANALYSIS USED

Comparison of the results was made using Levene and analysis of variance tests (α =0.05).

RESULTS

Irrespective of the material tested, statistical differences were found between the measuring techniques (P = 0.001 overall); the obtained mean gaps were for CT scan (92.60 ± 13.31), for SEM (101.92 ± 23.03), and for SM (113.44 ± 14.68): the multiple comparisons between techniques found a significant difference between CT and SM (P < 0.001), and SEM and SM (P = 0.025). When materials were compared within each measuring technique, Co-Cr showed lower values compared to zirconia in SEM (P < 0.001) and Stereo (P = 0.049); similar results were found in CT.

CONCLUSIONS

Results values differed with the chosen measuring technique. Co-Cr prostheses had a better fit than zirconia prostheses in SEM and Stereo. µCT showed comparable results to SEM, smaller than SM results.

摘要

目的

本研究的目的是通过微计算机断层扫描(μCT)、扫描电子显微镜(SEM)和立体显微镜(SM)比较预烧结氧化锆和钴铬修复体的适应性。

材料和方法

从上颌第一前磨牙和第一磨牙制备的典型模型上制作 24 个固定义齿(FDP),在金属基台上制作,复制到模型上。将牙齿减少以获得 1.2mm 的斜面和 2mm 的牙合面减少。通过随机分配将基台扫描到两组中,一组接受软铣 Co-Cr(n=12)制成的 FDP,另一组接受氧化锆(n=12)制成的 FDP。使用三种评估技术(X 射线微计算机断层扫描、SEM 和立体显微镜)评估边缘和内部间隙。

统计学分析

使用 Levene 和方差分析检验(α=0.05)比较结果。

结果

无论测试材料如何,测量技术之间均存在统计学差异(总体 P=0.001);获得的平均间隙为 CT 扫描(92.60±13.31)、SEM(101.92±23.03)和 SM(113.44±14.68):技术之间的多次比较发现 CT 和 SM 之间存在显著差异(P<0.001),SEM 和 SM 之间存在显著差异(P=0.025)。当在每种测量技术中比较材料时,Co-Cr 在 SEM(P<0.001)和 Stereo(P=0.049)中显示出比氧化锆更低的值;在 CT 中也得到了类似的结果。

结论

结果值因所选测量技术而异。Co-Cr 修复体在 SEM 和 Stereo 中的拟合效果优于氧化锆修复体。µCT 与 SEM 结果相当,小于 SM 结果。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验