Our aim was to determine the number and size parameters of EDB motor units in healthy young adults using MScanFit, a novel approach to motor unit number estimation (MUNE). Since variability in MUNE is related to compound muscle action potential (CMAP) size, we employed a procedure to document the optimal EDB electromyographic (EMG) electrode position prior to recording MUNE, a neglected practice in MUNE.
Subjects were 21 adults 21-44 y. Maximum CMAPs were recorded from 9 sites in a 4 cm2 region centered over the EDB and the site with the largest amplitude was used in the MUNE experiment. For MUNE, the peroneal nerve was stimulated at the fibular head to produce a detailed EDB stimulus-response curve or "MScan". Motor unit number and size parameters underlying the MScan were simulated using the MScanFit mathematical model.
In 19 persons, the optimal recording site was superior, superior and proximal, or superior and distal to the EDB mid-belly, whereas in 3 persons it was proximal to the mid-belly. Ranges of key MScanFit parameters were as follows: maximum CMAP amplitude (3.1-8.5 mV), mean SMUP amplitude (34.4-106.7 μV), mean normalized SMUP amplitude (%CMAP max, 0.95-2.3%), largest SMUP amplitude (82.7-348 μV), and MUNE (43-103). MUNE was not related to maximum CMAP amplitude (R2 = 0.09), but was related to mean SMUP amplitude (R2 = -0.19, P = 0.05).
The EDB CMAP was highly sensitive to electrode position, and the optimal position differed between subjects. Individual differences in EDB MUNE were not related to CMAP amplitude. Inter-subject variability of EDB MUNE (coefficient of variation) was much less than previously reported, possibly explained by better optimization of the EMG electrode and the unique approach of MScanFit MUNE.
我们旨在使用 MScanFit 确定健康年轻成年人中 EDB 运动单位的数量和大小参数,这是一种新的运动单位数量估计(MUNE)方法。由于 MUNE 的变异性与复合肌肉动作电位(CMAP)大小有关,因此我们采用了一种在记录 MUNE 之前记录 EDB 肌电图(EMG)电极最佳位置的程序,这是 MUNE 中被忽视的做法。
研究对象为 21 名 21-44 岁的成年人。在以 EDB 为中心的 4 cm2 区域内的 9 个部位记录最大 CMAP,并在 MUNE 实验中使用幅度最大的部位。对于 MUNE,在腓骨头处刺激腓神经以产生详细的 EDB 刺激-反应曲线或“MScan”。使用 MScanFit 数学模型模拟 MScan 下的运动单位数量和大小参数。
在 19 人中,最佳记录部位在 EDB 中腹部的上方、上方和近端,或者在上方和远端,而在 3 人中,记录部位在中腹部的近端。关键 MScanFit 参数的范围如下:最大 CMAP 幅度(3.1-8.5 mV)、平均 SMUP 幅度(34.4-106.7 μV)、平均归一化 SMUP 幅度(%CMAP max,0.95-2.3%)、最大 SMUP 幅度(82.7-348 μV)和 MUNE(43-103)。MUNE 与最大 CMAP 幅度无关(R2 = 0.09),但与平均 SMUP 幅度有关(R2 = -0.19,P = 0.05)。
EDB CMAP 对电极位置非常敏感,最佳位置因人而异。EDB MUNE 的个体差异与 CMAP 幅度无关。EDB MUNE 的个体间变异性(变异系数)远小于先前的报告,这可能是由于更好地优化了 EMG 电极和 MScanFit MUNE 的独特方法。