School of Chemical Engineering, University of New South Wales, Sydney 2052, NSW, Australia; School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney 2008, NSW, Australia.
School of Chemical Engineering, University of New South Wales, Sydney 2052, NSW, Australia.
Ultrason Sonochem. 2024 Jun;106:106885. doi: 10.1016/j.ultsonch.2024.106885. Epub 2024 Apr 23.
This research designed and developed an ultrasonic reactor for a fast and on demand production of cold brew coffee, remarkably reducing the brewing time from 24 h to less than 3 min. The technology was engineered by utilizing resonance to induce ultrasonic waves around the walls of the brewing basket of an espresso machine. The sound transmission system comprised a transducer, a horn and a brewing basket. This arrangement transformed the coffee basket into an effective sonoreactor that injected sound waves at multiple points through its walls, thereby generating multiple regions for acoustic cavitation within the reactor. Furthermore, acoustic streaming induced greater mixing and enhanced mass transfer during brewing. The design was accomplished by modeling the transmission of sound, and acoustic cavitation. Brew characterization and chemical composition analysis was performed, considering factors such as pH, acidity, color, and the composition of caffeine, fatty acids, and volatiles. The efficiency of the extraction increased by decreasing the basket loading percentage (BLP). For instance, sonicating at 100 W doubled the extraction yield and caffeine concentration, from 15.05 % to 33.44 % at BLP = 33 %, and from 0.91 mg/mL to 1.84 mg/mL at BLP = 67 %, respectively. The total fatty acids increased from 1.16 mg/mL to 9.20 mg/mL, representing an eightfold increase, at BLP = 33 %. Finally, a sensory analysis was conducted to evaluate appearance, aroma, texture, flavor, and aftertaste, which demonstrated that coffee brewed for 1 and 3 min in the sonoreactor exhibited almost undistinguishable properties compared to a standard 24 h brewing without ultrasound.
本研究设计并开发了一种用于快速按需生产冷萃咖啡的超声反应器,将酿造时间从 24 小时显著缩短至不到 3 分钟。该技术通过利用共振在浓缩咖啡机的酿造篮周围产生超声波来实现。该声传输系统包括换能器、喇叭和酿造篮。这种布置将咖啡篮变成了一个有效的声反应器,通过其壁在多个点注入声波,从而在反应器内产生多个声学空化区域。此外,声流在酿造过程中引起更大的混合和增强传质。通过对声传输和空化进行建模来完成设计。对酿造特征和化学成分分析进行了考虑,考虑了 pH 值、酸度、颜色以及咖啡因、脂肪酸和挥发性成分的组成等因素。通过降低篮装载百分比(BLP)可以提高提取效率。例如,在 100W 下超声处理时,BLP 为 33%时,提取产率和咖啡因浓度分别从 15.05%增加到 33.44%,从 0.91mg/mL 增加到 1.84mg/mL;BLP 为 67%时,总脂肪酸从 1.16mg/mL 增加到 9.20mg/mL,增加了 8 倍。最后,进行了感官分析以评估外观、香气、质地、口感和余味,结果表明,在声反应器中酿造 1 分钟和 3 分钟的咖啡与未经超声的标准 24 小时酿造相比,几乎没有区别。