Department of Health of San Juan de Alicante, Provincial-Pla Hospital, Spain.
Department of Clinical Medicine, Miguel Hernández University, Elche, Spain; Network for Research on Chronicity, Primary Care, and Health Promotion (RICAPPS), Spain.
Prim Care Diabetes. 2024 Jun;18(3):333-339. doi: 10.1016/j.pcd.2024.04.003. Epub 2024 Apr 26.
We aimed to evaluate the utility of the FreeStyle Libre 2 device for reducing time below range level 1 and level 2 compared with the Freestyle Libre device (without alarms) in people with type 1 diabetes mellitus. We conducted longitudinal observational follow-up study of a cohort of 100 people with type 1 diabetes mellitus who had switched from FreeStyle Libre to FreeStyle Libre 2 as part of routine clinical practice. Three months after switching to FreeStyle Libre 2, compared with results with FreeStyle Libre, there were a significant improvements in time below range level 1 (p = 0.02) and level 2 (p <0.001), time in range (p <0.001), time above range level 1 (p = 0.002), glucose management indicator (p= 0.04) and mean glucose (p= 0.04) during follow-up. Furthermore there was a significant direct association between age and change in TIR with a coefficient of 0.23, and a significant inverse association between age and change in TAR-1 with a coefficient of 0.11. Switching to a flash glucose monitoring system with alarms improves time below range, time in range and coefficient of variation in people with type 1 diabetes mellitus.
我们旨在评估与不带报警功能的 FreeStyle Libre 相比,FreeStyle Libre 2 设备在 1 型糖尿病患者中降低 1 级和 2 级血糖下限水平的效果。我们对 100 名 1 型糖尿病患者进行了纵向观察性随访研究,这些患者在常规临床实践中已从 FreeStyle Libre 切换到 FreeStyle Libre 2。与 FreeStyle Libre 相比,在切换到 FreeStyle Libre 2 3 个月后,1 级(p = 0.02)和 2 级(p <0.001)血糖下限时间、血糖达标时间(p <0.001)、1 级血糖上限时间(p = 0.002)、血糖管理指标(p= 0.04)和平均血糖(p= 0.04)均有显著改善。此外,年龄与 TIR 变化之间存在显著的直接关联,系数为 0.23,年龄与 TAR-1 变化之间存在显著的负相关,系数为 0.11。切换到带报警功能的即时血糖监测系统可改善 1 型糖尿病患者的血糖下限时间、血糖达标时间和变异系数。