Abstract

Skin color observation provides a simple and non-invasive method to estimate the health status of patients. Capillary Refill Time (CRT) is widely used as an indicator of pathophysiological conditions, especially in emergency patients. While the measurement of CRT is easy to perform, its evaluation is highly subjective. This study proposes a method to aid quantified CRT measurement using an RGB camera. The procedure consists in applying finger compression to the forearm, and the CRT is calculated based on the skin color change after the pressure release. We estimate compression applied by a finger from its fingernail color change during compression. Our study shows a step towards camera-based quantitative CRT for untrained individuals.

摘要

肤色观察为评估患者健康状况提供了一种简单且无创的方法。毛细血管再充盈时间(Capillary Refill Time,CRT)被广泛用作生理病理状况的指标,尤其是在急诊患者中。虽然 CRT 的测量很容易进行,但它的评估具有高度主观性。本研究提出了一种使用 RGB 相机辅助 CRT 定量测量的方法。该方法包括对手臂施加指压,然后根据压力释放后皮肤颜色的变化来计算 CRT。我们通过手指在按压过程中指甲颜色的变化来估计按压的程度。我们的研究朝着为非专业人员实现基于相机的 CRT 定量测量迈出了一步。

相似文献

1
Quantitative Capillary Refill Time with image-based finger force estimation.
Med Eng Phys. 2024 May;127:104168. doi: 10.1016/j.medengphy.2024.104168. Epub 2024 Apr 16.
2
Evaluation of Automated Finger Compression for Capillary Refill Time Measurement in Pediatrics.
Pediatr Emerg Care. 2024 Aug 1;40(8):586-590. doi: 10.1097/PEC.0000000000003183. Epub 2024 Jun 14.
3
Skin-color-independent robust assessment of capillary refill time.
J Biophotonics. 2023 Nov;16(11):e202300063. doi: 10.1002/jbio.202300063. Epub 2023 Aug 10.
4
Capillary refill time is an unreliable indicator of cardiovascular status in term neonates.
Adv Neonatal Care. 2005 Jun;5(3):147-54. doi: 10.1016/j.adnc.2005.02.008.
5
Full Finger Reperfusion Time Measured by Pulse Oximeter Waveform Analysis in Children.
Crit Care Med. 2020 Oct;48(10):e927-e933. doi: 10.1097/CCM.0000000000004506.
6
Variability of Capillary Refill Time among Physician Measurements.
J Emerg Med. 2017 Nov;53(5):e51-e57. doi: 10.1016/j.jemermed.2017.06.035. Epub 2017 Sep 21.
7
Validity and reliability of measurement of capillary refill time in children: a systematic review.
Arch Dis Child. 2015 Mar;100(3):239-49. doi: 10.1136/archdischild-2014-307079. Epub 2014 Sep 26.
8
An automated quasi-continuous capillary refill timing device.
Physiol Meas. 2016 Jan;37(1):83-99. doi: 10.1088/0967-3334/37/1/83. Epub 2015 Dec 7.
9
Evaluation of accuracy of capillary refill index with pneumatic fingertip compression.
J Clin Monit Comput. 2021 Feb;35(1):135-145. doi: 10.1007/s10877-019-00454-1. Epub 2020 Jan 8.
10
Reliability of capillary refill time for evaluation of tissue perfusion in simulated vascular occluded limbs.
Eur J Trauma Emerg Surg. 2022 Apr;48(2):1231-1237. doi: 10.1007/s00068-020-01594-9. Epub 2021 Jan 21.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验