We devised a split-bolus injection and imaging protocol for pulmonary artery and vein separation computed tomography (CT) angiography based on time enhancement curve characterization. Furthermore, we aimed to evaluate the contrast enhancement effect and success rate of blood vessel separation between the pulmonary artery and vein of this proposed protocol.
In this study, 102 patients (45 patients with the standard protocol and 57 patients with the proposed protocol) who underwent pulmonary arteriovenous computed tomography angiography were included. The CT values of various vessels, CT value difference between the pulmonary trunk and left atrium, and coefficient of variation in pulmonary arteries and veins were obtained from images of the standard and proposed protocols.
The CT values in the proposed protocol for the pulmonary trunk were significantly higher than those in the standard protocol (487.3 [415.5-546.9] HU vs. 293.0 [259.0-350.0] HU, P < 0.01). The CT value difference between the pulmonary trunk and left atrium in the proposed protocol was significantly higher than that in the conventional protocol (211.3 [158.0-265.7] HU vs. 32 [-30.0-55.0] HU, P < 0.01). The coefficient of variation in the proposed protocol was 0.08 (0.06-0.10) and 0.09 (0.08-0.11) in pulmonary arteries and 0.08 (0.06-0.09) and 0.09 (0.07-0.12) in pulmonary veins, respectively.
The proposed protocol achieved separation between the pulmonary artery and vein in many patients, making it useful for the preoperative assessment of individual thoracic anatomy.
我们基于时间增强曲线特征设计了一种用于肺动脉和静脉分离计算机断层扫描(CT)血管造影的分次团注注射及成像方案。此外,我们旨在评估该方案在肺动脉和静脉之间的对比增强效果及血管分离成功率。
本研究纳入了102例行肺动静脉计算机断层扫描血管造影的患者(45例采用标准方案,57例采用所提出的方案)。从标准方案和所提出方案的图像中获取各种血管的CT值、肺动脉主干与左心房之间的CT值差异以及肺动脉和静脉的变异系数。
所提出方案中肺动脉主干的CT值显著高于标准方案(487.3 [415.5 - 546.9] HU对293.0 [259.0 - 350.0] HU,P < 0.01)。所提出方案中肺动脉主干与左心房之间的CT值差异显著高于传统方案(211.3 [158.0 - 265.7] HU对32 [-30.0 - 55.0] HU,P < 0.01)。所提出方案中肺动脉的变异系数分别为0.08(0.06 - 0.10)和0.09(0.08 - 0.11),肺静脉的变异系数分别为0.08(0.06 - 0.09)和0.09(0.07 - 0.12)。
所提出的方案在许多患者中实现了肺动脉和静脉的分离,对个体胸部解剖结构的术前评估具有重要价值。