Suppr超能文献

使用多参数磁共振成像对人乳腺癌异种移植模型中动脉内注射曲妥珠单抗进行早期治疗评估。

Early therapy evaluation of intra-arterial trastuzumab injection in a human breast cancer xenograft model using multiparametric MR imaging.

作者信息

Kim Bo Kyu, Kim Byungjun, You Sung-Hye, Jang Moon-Sun, Im Geun Ho, Kim Keon-Ha

机构信息

Department of Radiology, Korea University Anam Hospital, Seoul, Korea.

Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine and Center for Molecular and Cellular Imaging, Samsung Biomedical Research Institute, Seoul, Korea.

出版信息

PLoS One. 2024 May 3;19(5):e0300171. doi: 10.1371/journal.pone.0300171. eCollection 2024.

Abstract

PURPOSE

To investigate the treatment efficacy of intra-arterial (IA) trastuzumab treatment using multiparametric magnetic resonance imaging (MRI) in a human breast cancer xenograft model.

MATERIALS AND METHODS

Human breast cancer cells (BT474) were stereotaxically injected into the brains of nude mice to obtain a xenograft model. The mice were divided into four groups and subjected to different treatments (IA treatment [IA-T], intravenous treatment [IV-T], IA saline injection [IA-S], and the sham control group). MRI was performed before and at 7 and 14 d after treatment to assess the efficacy of the treatment. The tumor volume, apparent diffusion coefficient (ADC), and dynamic contrast-enhanced (DCE) MRI parameters (Ktrans, Kep, Ve, and Vp) were measured.

RESULTS

Tumor volumes in the IA-T group at 14 d after treatment were significantly lower than those in the IV-T group (13.1 mm3 [interquartile range 8.48-16.05] vs. 25.69 mm3 [IQR 20.39-30.29], p = 0.005), control group (IA-S, 33.83 mm3 [IQR 32.00-36.30], p<0.01), and sham control (39.71 mm3 [IQR 26.60-48.26], p <0.001). The ADC value in the IA-T group was higher than that in the control groups (IA-T, 7.62 [IQR 7.23-8.20] vs. IA-S, 6.77 [IQR 6.48-6.87], p = 0.044 and vs. sham control, 6.89 [IQR 4.93-7.48], p = 0.004). Ktrans was significantly decreased following the treatment compared to that in the control groups (p = 0.002 and p<0.001 for vs. IA-S and sham control, respectively). Tumor growth was decreased in the IV-T group compared to that in the sham control group (25.69 mm3 [IQR 20.39-30.29] vs. 39.71 mm3 [IQR 26.60-48.26], p = 0.27); there was no significant change in the MRI parameters.

CONCLUSION

IA treatment with trastuzumab potentially affects the early response to treatment, including decreased tumor growth and decrease of Ktrans, in a preclinical brain tumor model.

摘要

目的

在人乳腺癌异种移植模型中,使用多参数磁共振成像(MRI)研究动脉内(IA)注射曲妥珠单抗的治疗效果。

材料与方法

将人乳腺癌细胞(BT474)立体定向注射到裸鼠脑内以获得异种移植模型。将小鼠分为四组并进行不同治疗(IA治疗[IA-T]、静脉注射治疗[IV-T]、IA注射生理盐水[IA-S]以及假手术对照组)。在治疗前以及治疗后7天和14天进行MRI检查以评估治疗效果。测量肿瘤体积、表观扩散系数(ADC)以及动态对比增强(DCE)MRI参数(Ktrans、Kep、Ve和Vp)。

结果

治疗后14天,IA-T组的肿瘤体积显著低于IV-T组(13.1立方毫米[四分位间距8.48 - 16.05] 对比25.69立方毫米[四分位间距20.39 - 30.29],p = 0.005)、对照组(IA-S,33.83立方毫米[四分位间距32.00 - 36.30],p <0.01)以及假手术对照组(39.71立方毫米[四分位间距26.60 - 48.26],p <0.001)。IA-T组的ADC值高于对照组(IA-T,7.62[四分位间距7.23 - 8.20] 对比IA-S,6.77[四分位间距6.48 - 6.87],p = 0.044;对比假手术对照组,6.89[四分位间距4.93 - 7.48],p = 0.004)。与对照组相比,治疗后Ktrans显著降低(与IA-S组和假手术对照组相比,p分别为0.002和p <0.001)。与假手术对照组相比,IV-T组的肿瘤生长减缓(25.69立方毫米[四分位间距20.39 - 30.29] 对比39.71立方毫米[四分位间距26.60 - 48.26],p = 0.27);MRI参数无显著变化。

结论

在临床前脑肿瘤模型中,IA注射曲妥珠单抗治疗可能影响治疗的早期反应,包括肿瘤生长减缓以及Ktrans降低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b446/11068173/52404360dbd9/pone.0300171.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验