To evaluate the performance of a newly developed 2019-nCoV nucleic acid detection kit based on Ion Proton sequencing platform and make comparation with MGI Tech (DNBSEQ-G99) platform.
References and clinical samples were used to evaluate the precision, agreement rate, limit of detection (LOD), anti-interference ability and analytical specificity. Twenty-seven clinical specimens were used to make comparison between two platforms.
The kit showed good intra-assay, inter-assay, inter-day precision between different operators and laboratories, fine agreement rate with references, a relatively low LOD of 1 × 10 copies/ml, anti-interference capability of 5 % whole blood and 1mg/ml mucin and no cross reaction with twenty-nine common clinical pathogens. Consistency of variant classification was observed between two platforms. The WGS from Ion Proton tended to have higher coverage and less missing data.
The newly developed kit has shown satisfactory performances and excellent consistency with DNBSEQ-G99, making it a good alternative choice clinically.
评估一种基于 Ion Proton 测序平台的新型 2019-nCoV 核酸检测试剂盒的性能,并与 MGI Tech(DNBSEQ-G99)平台进行比较。
参考品和临床样本用于评估精密度、符合率、检测限(LOD)、抗干扰能力和分析特异性。用 27 份临床标本对两种平台进行比较。
该试剂盒显示出良好的室内精密度、室间精密度、不同操作者和实验室间日间精密度,与参考品有很好的符合率,相对较低的 LOD 为 1×10 拷贝/ml,对 5%全血和 1mg/ml 粘蛋白的抗干扰能力,与 29 种常见临床病原体无交叉反应。两种平台的变异分类一致性良好。Ion Proton 的 WGS 测序具有更高的覆盖率和更少的缺失数据。
新型试剂盒与 DNBSEQ-G99 相比,具有令人满意的性能和出色的一致性,是临床上的一种较好的替代选择。