Suppr超能文献

CT引导下肾上腺活检:准确性、安全性及适应证

CT-guided adrenal biopsy: accuracy, safety, and indications.

作者信息

Bernardino M E, Walther M M, Phillips V M, Graham S D, Sewell C W, Gedgaudas-McClees K, Baumgartner B R, Torres W E, Erwin B C

出版信息

AJR Am J Roentgenol. 1985 Jan;144(1):67-9. doi: 10.2214/ajr.144.1.67.

Abstract

Fifty-eight percutaneous needle biopsies of adrenal masses were performed in 53 patients. The technique was initially successful in 44 (83%) of 53 patients. Five patients had second procedures because of initial failure or the possibility of sampling error. Fourteen biopsies were performed in nononcologic patients and 39 in patients with a known malignancy. None of the adrenal masses in nononcologic patients were malignant. Only 18 (46.1%) of the 39 masses in oncologic patients were metastases; the rest represented a variety of nonneoplastic conditions. Seven minor complications occurred in six patients. Two of these patients required transfusions for hypotension or decreases in hematocrit. No correlation was noted between needle size and complications. There were no pneumothoraces. The procedure is an accurate and safe alternative to surgical biopsy.

摘要

对53例患者的肾上腺肿块进行了58次经皮针吸活检。该技术最初在53例患者中的44例(83%)取得成功。5例患者因初次活检失败或存在取样误差而进行了二次活检。14例活检针对非肿瘤患者,39例针对已知患有恶性肿瘤的患者。非肿瘤患者的肾上腺肿块均无恶性病变。肿瘤患者的39个肿块中只有18个(46.1%)为转移瘤;其余表现为各种非肿瘤性病变。6例患者出现7次轻微并发症。其中2例患者因低血压或血细胞比容降低需要输血。未发现针的大小与并发症之间存在关联。未发生气胸。该方法是手术活检的一种准确且安全的替代方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验