Suppr超能文献

快速经手臂静脉注入造影剂所致的下腔静脉CT假血栓形成。

Inferior vena cava CT pseudothrombus produced by rapid arm-vein contrast infusion.

作者信息

Vogelzang R L, Gore R M, Neiman H L, Smith S J, Deschler T W, Vrla R F

出版信息

AJR Am J Roentgenol. 1985 Apr;144(4):843-6. doi: 10.2214/ajr.144.4.843.

Abstract

Laminar flow within the inferior vena cava can cause artifacts that may simulate thrombus if a foot-vein infusion is used. A "pseudothrombus" artifact within the suprarenal inferior vena cava produced by rapid infusion of contrast material through an arm vein is reported. This artifact was noted in 25 patients in a 6 month period and was believed to be from laminar flow of renal venous effluent of increased opacity around less opacified infrarenal caval contents. Differentiation from true thrombus can be made by the use of delayed scans as well as the increased density and relatively poor margination of the artifact.

摘要

如果使用足静脉输注,下腔静脉内的层流可导致伪影,可能会模拟血栓。本文报道了经手臂静脉快速注入造影剂后,在肾上腺水平以下的下腔静脉内产生的“假血栓”伪影。在6个月的时间里,在25例患者中发现了这种伪影,其被认为是由于肾静脉流出物的层流,使得肾下腔内容物周围的密度增加,而这些内容物的密度较低。通过延迟扫描以及伪影的密度增加和边缘相对不清,可以与真正的血栓相鉴别。