Abstract

INTRODUCTION

Nickel-titanium rotary endodontic files have been commercially available for decades, but more recent innovations have introduced heat-treated and surface-treated files. This study investigated the corrosion properties of various nickel-titanium files in normal saline and sodium hypochlorite (NaOCl).

METHODS

Ten different file brands of size 40 with a 0.04 taper were subjected to electrochemical testing in 0.9% NaCl (saline) and 5.25% NaOCl at room temperature. The Open Circuit Potential (OCP) was observed for 1 hour followed by a cyclic polarization test from -300 to 700 mV and back to -300 mV (vs OCP). Nonparametric ANOVA and a pairwise comparison (P < .05) were used for statistical analysis of the OCP at 1 hour and the corrosion current (Icorr) obtained via the cyclic polarization test.

RESULTS

Significant differences (P < .05) were found between files with respect to OCP and Icorr in both solutions. Nine files exhibited significantly greater (P < .05) Icorrs in NaOCl than in saline. Conversely, pitting corrosion was observed in the saline solution but not NaOCl. Weak and/or moderate correlations existed between OCP and Icorr measures in the 2 solutions.

CONCLUSION

Significant differences in electrochemical properties were observed among the 10 brands of files. Overall, there was not a clear trend between conventional, heat-treated, or surface-treated files among OCP or Icorr in either solution.

摘要

简介

镍钛合金旋转根管锉已商业化应用数十年,但最近的创新技术引入了热处理和表面处理的锉。本研究调查了不同镍钛合金锉在生理盐水和次氯酸钠(NaOCl)中的腐蚀性能。

方法

对 10 种不同品牌、40 号、0.04 锥度的锉进行电化学测试,在室温下分别置于 0.9%氯化钠(生理盐水)和 5.25% NaOCl 中。观察 1 小时的开路电位(OCP),然后进行从-300 到 700 mV 的循环极化测试,并回到-300 mV(相对于 OCP)。非参数方差分析和两两比较(P <.05)用于统计分析 1 小时时的 OCP 和循环极化测试获得的腐蚀电流(Icorr)。

结果

在两种溶液中,OCP 和 Icorr 方面,各锉之间存在显著差异(P <.05)。9 种锉在 NaOCl 中的 Icorr 显著高于生理盐水(P <.05)。相反,在生理盐水溶液中观察到点蚀,但在 NaOCl 中没有。在两种溶液中,OCP 和 Icorr 之间存在弱到中度相关性。

结论

10 种锉的电化学性能存在显著差异。总体而言,在两种溶液中,OCP 或 Icorr 方面,常规、热处理或表面处理的锉之间没有明显的趋势。