Suppr超能文献

评估退伍军人医疗保健系统中 1 型糖尿病和 2 型糖尿病患者的连续血糖监测使用模式和血糖控制指标:将连续血糖监测设备数据与电子健康记录数据相结合。

Assessing Patterns of Continuous Glucose Monitoring Use and Metrics of Glycemic Control in Type 1 Diabetes and Type 2 Diabetes Patients in the Veterans Health Care System: Integrating Continuous Glucose Monitoring Device Data with Electronic Health Records Data.

机构信息

Department of Biostatistics, University of California, Los Angeles, Los Angeles, California, USA.

Phoenix VA Health Care System (111E), Phoenix, Arizona, USA.

出版信息

Diabetes Technol Ther. 2024 Nov;26(11):806-813. doi: 10.1089/dia.2024.0083. Epub 2024 Jun 11.

Abstract

To integrate long-term daily continuous glucose monitoring (CGM) device data with electronic health records (EHR) for patients with type 1 and type 2 diabetes (T1D and T2D) in the national Veterans Affairs Healthcare System to assess real-world patterns of CGM use and the reliability of EHR-based CGM information. This observational study used Dexcom CGM device data linked with EHR (from 2015 to 2020) for a large national cohort of patients with diabetes. We tracked the initiation and consistency of CGM use, assessed concordance of CGM use and measures of glucose control between CGM device data and EHR records, and examined results by age, ethnicity, and diabetes type. The time from pharmacy release of CGM to patients to initiation of uploading CGM data to Dexcom servers averaged 3 weeks but demonstrated wide variation among individuals; importantly, this delay decreased markedly over the later years. The average daily wear time of CGM exceeded 22 h over nearly 3 years of follow-up. Patterns of CGM use were generally consistent across age, race/ethnicity groups, and diabetes type. There was strong concordance between EHR-based estimates of CGM use and Dexcom CGM wear time and between estimates of glucose control from both sources. The study demonstrates our ability to reliably integrate CGM devices and EHR data to provide valuable insights into CGM use patterns. The results indicate in the real-world environment that CGM is worn consistently over many years for both patients with T1D and T2D within the Veterans Affairs Healthcare System and is similar across major race/ethnic groups and age-groups.

摘要

将长期日常连续血糖监测 (CGM) 设备数据与退伍军人事务部医疗保健系统中 1 型和 2 型糖尿病 (T1D 和 T2D) 患者的电子健康记录 (EHR) 整合,以评估 CGM 使用的真实模式和基于 EHR 的 CGM 信息的可靠性。这项观察性研究使用 Dexcom CGM 设备数据与 EHR 相关联(2015 年至 2020 年),针对糖尿病的大型全国患者队列进行研究。我们跟踪了 CGM 使用的开始和一致性,评估了 CGM 使用与 CGM 设备数据和 EHR 记录中血糖控制测量之间的一致性,并按年龄、族裔和糖尿病类型检查了结果。CGM 从药房发放给患者到开始将数据上传到 Dexcom 服务器的时间平均为 3 周,但个体之间差异很大;重要的是,这种延迟在后来的几年中明显减少。CGM 的平均每日佩戴时间在近 3 年的随访中超过 22 小时。CGM 使用模式在年龄、种族/族裔群体和糖尿病类型方面总体上是一致的。EHR 基于 CGM 使用的估计值与 Dexcom CGM 佩戴时间之间以及两个来源的血糖控制估计值之间具有很强的一致性。该研究证明了我们能够可靠地整合 CGM 设备和 EHR 数据,从而为 CGM 使用模式提供有价值的见解。结果表明,在现实环境中,CGM 在退伍军人事务部医疗保健系统中,T1D 和 T2D 患者多年来一直持续佩戴,并且在主要种族/族裔群体和年龄组之间相似。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验