A new sandwich-type electrochemical biosensing platform was developed by gold @polyphthalenediamine nanohybrids (AuNP@PoPD) as the sensing platform and phosphorus doped reduced graphene oxide-hemin-palladium nanoparticles (PrGO-Hemin-PdNP) as the signal amplifier for phosphatidylinositol proteoglycan 3 (GPC3). AuNP@PoPD, co-electrodeposited into the screen printed electrode with high conductivity and stability, is dedicated to assembling the primary GPC3 aptamer (GPC3). The second GPC3 immobilized on the high conductivity and large surface area of PrGO-Hemin-PdNP was utilized as an electrochemical signal reporter by hemin oxidation (PrGO-Hemin-PdNP-GPC3). In the range 0.001-10.0 ng/mL, the hemin oxidation current signal of the electrochemical aptasensor increased log-linearly with the concentration of GPC3, the lowest detection limit was 0.13 pg/mL, and the sensitivity was 2.073 μA/μM/cm. The aptasensor exhibited good sensing performance in a human serum sample with the relative error of 4.31-8.07%. The sandwich sensor showed good selectivity and stability for detection GPC3 in human serum samples, providing a new efficient and sensitive method for detecting HCC markers.

摘要

一种新型三明治型电化学生物传感平台由金纳米粒子@聚对苯二胺纳米杂化物(AuNP@PoPD)作为传感平台和磷掺杂还原氧化石墨烯-血红素-钯纳米粒子(PrGO-Hemin-PdNP)作为信号放大器用于磷脂酰肌醇聚糖蛋白 3(GPC3)。AuNP@PoPD,与高导电性和高稳定性的丝网印刷电极共电沉积,专门用于组装初级 GPC3 适体(GPC3)。第二个 GPC3 固定在高导电性和大表面积的 PrGO-Hemin-PdNP 上,通过血红素氧化(PrGO-Hemin-PdNP-GPC3)用作电化学信号报告器。在 0.001-10.0 ng/mL 范围内,电化学适体传感器的血红素氧化电流信号与 GPC3 的浓度呈对数线性增加,最低检测限为 0.13 pg/mL,灵敏度为 2.073 μA/μM/cm。该适体传感器在人血清样品中表现出良好的传感性能,相对误差为 4.31-8.07%。夹心传感器对人血清样品中 GPC3 的检测表现出良好的选择性和稳定性,为检测 HCC 标志物提供了一种新的高效灵敏方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验