Suppr超能文献

有和无单侧慢性颈部疼痛个体的颈多裂肌僵硬程度评估:一项检查者间可靠性研究

Cervical Multifidus Stiffness Assessment in Individuals with and without Unilateral Chronic Neck Pain: An Inter-Examiner Reliability Study.

作者信息

Varol Umut, Valera-Calero Juan Antonio, Ortega-Santiago Ricardo, López-Redondo Mónica, Navarro-Santana Marcos José, Plaza-Manzano Gustavo, Belón-Pérez Pedro

机构信息

Escuela Internacional de Doctorado, Universidad Rey Juan Carlos, 28922 Alcorcón, Spain.

Department of Radiology, Rehabilitation and Physiotherapy, Complutense University of Madrid, 28040 Madrid, Spain.

出版信息

Bioengineering (Basel). 2024 May 16;11(5):500. doi: 10.3390/bioengineering11050500.

Abstract

This study aimed to evaluate the inter-examiner reliability of shear wave elastography (SWE) for measuring cervical multifidus (CM) muscle stiffness in asymptomatic controls and patients with chronic neck pain. A longitudinal observational study was conducted to assess the diagnostic accuracy of a procedure. SWE images, following a detailed procedure previously tested, were acquired by two examiners (one novice and one experienced) to calculate the shear wave speed (SWS) and Young's modulus. The painful side was examined for the experimental cases while the side examined in the control group was selected randomly. Data analyses calculated the intra-class correlation coefficients (ICCs), absolute errors between examiners, standard errors of measurement, and minimal detectable changes. A total of 125 participants were analyzed ( = 54 controls and = 71 cases). The Young's modulus and SWS measurements obtained by both examiners were comparable within the asymptomatic group (both, > 0.05) and the chronic neck pain group (both, > 0.05). Nonetheless, a notable distinction was observed in the absolute error between examiners for shear wave speed measurements among patients with neck pain, where a significant difference was registered ( = 0.045), pointing to a sensitivity in measurement consistency affected by the presence of chronic neck pain. ICCs demonstrated moderate-to-good reliability across both groups, with ICC values for asymptomatic individuals reported as >0.8. Among the chronic neck pain patients, ICC values were slightly lower (>0.780). The study revealed moderate-to-good consistency, highlighting the practicality and generalizability of SWE.

摘要

本研究旨在评估剪切波弹性成像(SWE)在测量无症状对照者和慢性颈痛患者颈多裂肌(CM)肌肉硬度时检查者间的可靠性。进行了一项纵向观察性研究以评估一种检查方法的诊断准确性。按照先前测试过的详细流程,由两名检查者(一名新手和一名经验丰富的)采集SWE图像,以计算剪切波速度(SWS)和杨氏模量。对实验病例检查疼痛侧,而对照组则随机选择一侧进行检查。数据分析计算了组内相关系数(ICC)、检查者之间的绝对误差、测量标准误差和最小可检测变化。总共分析了125名参与者( = 54名对照者和 = 71例病例)。两名检查者获得的杨氏模量和SWS测量值在无症状组(两者, > 0.05)和慢性颈痛组(两者, > 0.05)内具有可比性。尽管如此,在颈痛患者的剪切波速度测量中,观察到检查者之间的绝对误差存在显著差异( = 0.045),这表明慢性颈痛的存在会影响测量一致性的敏感性。ICC在两组中均显示出中度至良好的可靠性,无症状个体的ICC值报告为 >0.8。在慢性颈痛患者中,ICC值略低(>0.780)。该研究显示出中度至良好的一致性,突出了SWE的实用性和可推广性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/296a/11118170/a37629276dea/bioengineering-11-00500-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验