Suppr超能文献

大鼠遥测检测和用于心血管安全性药理学评估的静脉导管接入按钮 - 手术方法、改进和群体维持。

The rat telemetry assay and venous catheter access buttons for use in cardiovascular safety pharmacology assessments - Surgical methods, refinements and colony maintenance.

机构信息

Vivonics Preclinical Ltd, Bio Support Unit, University of Nottingham, Sutton Bonington Campus, Loughborough, Leicestershire LE12 5RD, UK.

AM Pre-clinical Services Ltd, Macclesfield, Cheshire, UK.

出版信息

J Pharmacol Toxicol Methods. 2024 May-Jun;127:107517. doi: 10.1016/j.vascn.2024.107517. Epub 2024 May 24.

Abstract

INTRODUCTION

Rat telemetry is the assay of choice to assess the potential effects of novel drug candidates on cardiovascular parameters during early drug discovery. Telemetry device implantation can be combined with venous catheter and access button implantation when intravenous administration of the drug substance is required.

METHODS

Rats (Sprague Dawley or Han Wistar) were implanted with telemetry devices for arterial blood pressure measurement using either direct aortic catheterisation (n = 131) or aortic catheterisation via the femoral artery (n = 17). Bipolar leads for ECG recording were also implanted in some of the animals (n = 102). Femoral vein catheters and access buttons were implanted as a separate surgery after the initial telemetry implantation (n = 43).

RESULTS

128 animals (86%) were implanted successfully with telemetry devices without any notable surgical or post-surgical problems. When considering the 2 different catheterisation methods separately, the success rate of the direct aortic approach was 88% compared to 76% with the aortic placement via the femoral artery. Lameness was the most common post-surgical problem. Blood loss during surgery and ischaemic patches on the tail were also observed at a low incidence with the direct aortic approach. Catheter pull-out occurred in some rats before the first signal check reducing the overall success rate for blood pressure measurement using the direct aortic approach to 85%. A 95% success rate was observed for catheter and access button implantation.

DISCUSSION

A high success rate is possible when implanting telemetry devices in rats with and without venous catheters and access buttons. We have attempted to provide solutions to problems and describe refinements to the procedure which may further improve surgical outcomes.

摘要

简介

大鼠遥测是评估新药候选物对心血管参数潜在影响的首选方法,用于早期药物发现。当需要静脉给予药物时,遥测设备的植入可以与静脉导管和接入按钮的植入相结合。

方法

使用直接主动脉插管(n=131)或股动脉主动脉插管(n=17)为大鼠(Sprague Dawley 或 Han Wistar)植入用于动脉血压测量的遥测设备。一些动物还植入了用于心电图记录的双极导联(n=102)。股静脉导管和接入按钮在初始遥测植入后作为单独的手术植入(n=43)。

结果

128 只动物(86%)成功植入遥测设备,无明显手术或术后问题。分别考虑这 2 种不同的插管方法,直接主动脉入路的成功率为 88%,而经股动脉主动脉放置的成功率为 76%。跛行是最常见的术后问题。在直接主动脉入路中,手术期间失血和尾巴缺血斑块也观察到较低的发生率。在第一次信号检查之前,一些大鼠的导管拔出,这降低了使用直接主动脉入路测量血压的总体成功率至 85%。导管和接入按钮的植入成功率为 95%。

讨论

在植入带有和不带有静脉导管和接入按钮的大鼠的遥测设备时,成功率很高。我们试图提供解决问题的方法,并描述对程序的改进,这可能进一步提高手术结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验