Suppr超能文献

自体背侧镶嵌式软骨移植的吸收比较:一项实验研究。

Comparison of Resorption in Autogenous Dorsal Onlay Cartilage Grafts: An Experimental Study.

机构信息

Department of Otorhinolaryngology, Faculty of Medicine, Kastamonu University, 37150, Kastamonu, Turkey.

Department of Otorhinolaryngology, Faculty of Medicine, Dicle University, Diyarbakır, Turkey.

出版信息

Aesthetic Plast Surg. 2024 Nov;48(21):4333-4341. doi: 10.1007/s00266-024-04134-7. Epub 2024 May 28.

Abstract

OBJECTIVES

The present study was designed to compare the graft resorption characteristics of autogenous cartilage from the septum, auricle, and costal in the superficial muscular aponeurotic system of the nasal dorsum of the rabbit model.

METHODS

Equal-sized perichondrium-free septal, auricular, and costal cartilage grafts were collected from fifteen New Zealand white rabbits. Cartilage grafts were taken at the scale of two grafts from each animal's ear, two from its costal part, and one from its septum. Costal cartilage grafts that were shaped with a micro-motor device and monopolar electrocautery, elastic cartilage grafts that were shaped with a micro-motor device and monopolar electrocautery, and septal cartilage grafts that were shaped with a scalpel were all implanted into the dorsum of rabbit's noses to create five groups. All autogenous cartilage tissues were removed 3 months later. Cartilages were evaluated for histological features, graft mass, and chondrocyte density resorption.

RESULTS

The elastic cartilage group, where electrocautery was used to shape the cartilage, had a higher resorption score than the other groups. The costal cartilage graft shaped with a micro-motor was also observed to have the best cartilage regeneration score.

CONCLUSION

We observed that the resorption of costal cartilage was lower than that of ear and septum cartilage. It was determined that micro-motor application for the shaping process caused less resorption and stimulated more regeneration than cautery application.

LEVEL OF EVIDENCE III

This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

摘要

目的

本研究旨在比较兔模型鼻中隔、耳廓和肋软骨在鼻背浅表肌肉腱膜系统中的移植物吸收特性。

方法

从 15 只新西兰白兔中采集等大小的无软骨膜鼻中隔、耳廓和肋软骨移植物。从每只动物的耳朵上取两个软骨移植,从肋部取两个,从鼻中隔取一个。用微电机设备和单极电灼塑形肋软骨移植,用微电机设备和单极电灼塑形弹性软骨移植,用手术刀塑形鼻中隔软骨移植,均植入兔鼻背,共分为 5 组。3 个月后,所有自体软骨组织均被取出。对软骨进行组织学特征、移植物质量和软骨细胞密度吸收评估。

结果

用电灼塑形软骨的弹性软骨组吸收评分高于其他组。用微电机塑形的肋软骨移植物也观察到具有最佳的软骨再生评分。

结论

我们观察到肋软骨的吸收低于耳软骨和鼻中隔软骨。确定微电机应用于塑形过程引起的吸收较少,刺激再生较多,优于电灼应用。

证据水平 III:本杂志要求作者为每篇文章分配一个证据水平。有关这些循证医学评级的完整描述,请参阅目录或在线作者指南 www.springer.com/00266

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验