BACKGROUND

The aim of this study was to investigate the influence of abutment material, alveolar bone density, and occlusal forces on stress distribution around maxillary anterior implants.

MATERIALS AND METHODS

An study was conducted. The maxillary anterior implant was modeled using a three-dimensional finite element model in D2 and D3 bones with three different abutment materials: titanium, zirconia, and poly-ether-ether ketone (PEEK). Von Mises stress was evaluated after the application of vertical and oblique loads of 100 N, 175 N, and 250 N. Statistical analysis was done by Friedman-Wilcoxon signed-rank test, Mann-Whitney test, and Kruskal-Wallis test. The probability value <0.05 is considered a significant level.

RESULTS

Stress distribution around D3 bone was higher than D2 bone in all the abutment materials with greater values seen in oblique load than vertical load with insignificant difference ( > 0.05). Statistically insignificant stress values were seen greater in PEEK than titanium or zirconia abutment ( > 0.05). A statistically significant difference was observed between 100 N and 175 N of load ( < 0.05).

CONCLUSION

PEEK, zirconia, and titanium as abutment material in the anterior region showed similar properties. The stress on the bone was proportionately increased during the vertical and oblique loads suggesting the influence of mechanical load in crestal bone loss rather than the type of abutment material.

摘要

背景

本研究的目的是调查基台材料、牙槽骨密度和咬合力对上颌前牙种植体周围应力分布的影响。

材料与方法

进行了一项研究。使用三维有限元模型对D2和D3骨中的上颌前牙种植体进行建模,采用三种不同的基台材料:钛、氧化锆和聚醚醚酮(PEEK)。在施加100 N、175 N和250 N的垂直和斜向载荷后评估冯·米塞斯应力。通过Friedman-Wilcoxon符号秩检验、Mann-Whitney检验和Kruskal-Wallis检验进行统计分析。概率值<0.05被视为显著水平。

结果

在所有基台材料中,D3骨周围的应力分布高于D2骨,斜向载荷下的值大于垂直载荷下的值,但差异不显著(>0.05)。PEEK基台的应力值在统计学上比钛或氧化锆基台更大,但差异不显著(>0.05)。在100 N和175 N的载荷之间观察到统计学上的显著差异(<0.05)。

结论

PEEK、氧化锆和钛作为前牙区的基台材料表现出相似的特性。垂直和斜向载荷期间骨上的应力成比例增加,表明机械载荷对牙槽嵴骨吸收有影响,而非基台材料类型。