A long gas cell, filled with noble gas, is typically positioned between the undulator and the first mirror in the free-electron laser (FEL) beamline to attenuate the laser power as required by the end-stations. In addition to attenuation, the gas cell also serves important functions in various applications, such as spectrometer calibration, resolving power evaluation during beamline commissioning, and filtering of third harmonic in FEL operations. These functions of the gas cell have been successfully tested and implemented at the Dalian Coherent Light Source, a vacuum ultraviolet FEL facility located in Dalian, China. The resolving power of higher than 5000 has been obtained, and accurate calibration has been completed using the gas cell. During operation, the third harmonic of the FEL was attenuated by approximately one order of magnitude with almost the same power of the fundamental. This greatly improved the signal-to-noise ratio at the end-stations.
一个充满惰性气体的长气室通常位于自由电子激光(FEL)光束线的波荡器和第一反射镜之间,以根据终端站的要求衰减激光功率。除了衰减之外,气室在各种应用中还发挥着重要作用,例如光谱仪校准、光束线调试期间的分辨能力评估以及FEL运行中的三次谐波滤波。气室的这些功能已在位于中国大连的真空紫外FEL设施大连相干光源上成功测试并实现。已获得高于5000的分辨能力,并使用气室完成了精确校准。在运行期间,FEL的三次谐波被衰减了大约一个数量级,而基波功率几乎相同。这大大提高了终端站的信噪比。