Suppr超能文献

一种使用数字放射成像评估下腰椎横突椎弓根角度的新方法。

A novel method to evaluate the transverse pedicle angles of the lower lumbar vertebrae using digital radiography.

作者信息

Wu Shixun, Liu Shizhang, Ling Ming, Huang Minggang, Liu Zhe, Duan Xianglong

机构信息

Department of Orthopedics Surgery, Shaanxi Provincial People's Hospital, Xi'an, Shaanxi, China.

Key Laboratory of Bone Joint Disease Basic and Clinical Translation of Shaanxi Province, Xi'an, Shaanxi, China.

出版信息

PLoS One. 2024 Jun 13;19(6):e0295196. doi: 10.1371/journal.pone.0295196. eCollection 2024.

Abstract

To investigate a novel approach for establishing the transverse pedicle angle (TPA) of the lower lumbar spine using preoperative digital radiography (DR). Computed Tomography (CT) datasets of the lower lumbar were reconstructed using MIMICS 17.0 software and then imported into 3-matic software for surgical simulation and anatomical parameter measurement. A mathematical algorithm of TPA based on the Pythagorean theorem was established, and all obtained data were analyzed by SPSS software. The CT dataset from 66 samples was reconstructed as a digital model of the lower lumbar vertebrae (L3-L5), and the AP length/estimated lateral length for L3 between the right and left sides was statistically significant (P = 0.015, P = 0.005). The AP length of the right for L4 was smaller than that of the left after a paired t test was executed (P = 0.006). Both the width of the pedicle and the length of the pedicle (P2C1) were consistent with TPA (L3<L4<L5). There were no significant differences in TAN-TPA and DR-TPA compared with real TPA. The ICCs for the real TPA and DR-TPA within L3 showed good reliability, and the ICCs for the real TPA and DR-TPA within both L4 and L5 showed moderate reliability. Our novel approach can be considered a reliable way to determine the transverse pedicle angle from routine DR, and the width and length of the pedicle within lumbar DR should be considered to determine the length and trajectory of the screw during preoperative planning.

摘要

探讨一种利用术前数字X线摄影(DR)确定下腰椎横突间角(TPA)的新方法。使用MIMICS 17.0软件重建下腰椎的计算机断层扫描(CT)数据集,然后导入3-matic软件进行手术模拟和解剖参数测量。建立基于勾股定理的TPA数学算法,并使用SPSS软件对所有获得的数据进行分析。将66个样本的CT数据集重建为下腰椎(L3-L5)的数字模型,L3左右两侧的前后径长度/估计侧方长度具有统计学意义(P = 0.015,P = 0.005)。执行配对t检验后,L4右侧的前后径长度小于左侧(P = 0.006)。椎弓根宽度和椎弓根长度(P2C1)均与TPA一致(L3<L4<L5)。与真实TPA相比,TAN-TPA和DR-TPA无显著差异。L3内真实TPA和DR-TPA的组内相关系数(ICC)显示出良好的可靠性,L4和L5内真实TPA和DR-TPA的ICC显示出中等可靠性。我们的新方法可被视为一种从常规DR确定横突间角的可靠方法,在术前规划期间应考虑腰椎DR内椎弓根的宽度和长度,以确定螺钉的长度和轨迹。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/aaf5/11175444/aded97e819ac/pone.0295196.g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验