Department of Management, Economics and Industrial Engineering, Politecnico di Milano, Via Lambruschini 4/B, Milan, 20156, Italy.
Personalive srl, Via Durando 38, Milan, 20158, Italy.
BMC Health Serv Res. 2024 Jun 18;24(1):747. doi: 10.1186/s12913-024-11195-6.
The escalating prevalence of diabetes, with its multifaceted complications, poses a pressing challenge for healthcare systems globally. In response, the advent of continuous glucose monitoring (CGM) systems, offering technological solutions for daily diabetes management, presents significant opportunities. However, the widespread adoption faces several barriers, linked both to the technological configuration of the devices and to the psychological dimension of patients. Therefore, this study aims to apply and test a theoretical model that investigates the antecedents of the intention to use Continuous Glucose Monitoring systems.
The research model was built to unveil the impacts of psychological factors, functional components and rational constructs derived from the Technology Acceptance Model (TAM) on CGM systems sustained adoption. To ensure the comparability of results, we have collected data from people who had used Dexcom ONE Dexcom (San Diego, CA) for the first time for at least one month. Employing Structural Equation Modelling (SEM) techniques, the hypothesized relationships among constructs were assessed.
The analyses confirmed the positive correlation of rational factors to the Intention to Use. Subjective Norm, intended as the physicians' influence, is positively correlated with the Perceived Usefulness. Trend Arrows, albeit being negatively correlated with Perceived Usefulness, have a positive correlation on Perceived Ease Of Use, reinforcing its mediating effect towards Perceived Usefulness. Among psychological factors, Trust in the CGM technology positively correlates with Intention to Use. Health Literacy is negatively correlated to the Intention to Use.
These findings contribute to theoretical and managerial understanding, providing recommendations to enhance the adoption of CGM systems like Dexcom ONE.
糖尿病的患病率不断上升,其多种并发症给全球医疗保健系统带来了巨大挑战。为应对这一挑战,连续血糖监测(CGM)系统应运而生,为日常糖尿病管理提供了技术解决方案,具有重要意义。然而,该技术的广泛应用面临着一些障碍,这些障碍既与设备的技术配置有关,也与患者的心理因素有关。因此,本研究旨在应用和测试一个理论模型,该模型旨在研究连续血糖监测系统使用意愿的影响因素。
该研究模型旨在揭示心理因素、功能组件和源自技术接受模型(TAM)的理性结构对 CGM 系统持续采用的影响。为了确保结果的可比性,我们收集了首次使用 Dexcom ONE Dexcom(加利福尼亚州圣地亚哥)至少一个月的人的数据。采用结构方程建模(SEM)技术,评估了各构念之间假设关系的有效性。
分析结果证实了理性因素与使用意愿呈正相关。主观规范,即医生的影响,与感知有用性呈正相关。趋势箭头虽然与感知有用性呈负相关,但与感知易用性呈正相关,强化了其对感知有用性的中介作用。在心理因素方面,对 CGM 技术的信任与使用意愿呈正相关。健康素养与使用意愿呈负相关。
这些发现有助于理论和管理的理解,为增强 Dexcom ONE 等 CGM 系统的采用提供了建议。