Suppr超能文献

三维人体测量面部分析与体视摄影术和 CT 的拟合差异。

Three-Dimensional Anthropometric Facial Analysis and Fitting Discrepancies Between Stereophotogrammetry and CT.

机构信息

From the Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.

Department of Plastic and Reconstructive Surgery, Vanderbilt University Medical Center, Nashville, TN.

出版信息

Ann Plast Surg. 2024 Aug 1;93(2S Suppl 1):S82-S85. doi: 10.1097/SAP.0000000000003998. Epub 2024 Jun 17.

Abstract

BACKGROUND

The reliability and repeatability of stereophotogrammetry and CT in 3-dimensional anthropometric facial analysis were investigated in this study, which also explored the clinical application of supine CT.

METHOD

In this study, 3D CT and 3dMD stereophotogrammetry were used on 20 healthy volunteers. The fitting distance between stereophotogrammetry and CT scans at landmark points was measured, along with facial feature measurements (Al-Al) face width (Go-Go, Zy-Zy, Ex-Ex), and hemi-face height (Sn-Gn). The intraclass correlation coefficient (ICC) was employed to assess interrater agreement and to verify the reliability of the measurement methods. Paired t -analysis was utilized for analyzing intramethod displacement.

RESULTS

The alare, nasion, and pronasale points were found to be minimally influenced by different positions and are more recommended as landmark points for registration. CT demonstrated good interrater reliability on all indicators. In stereophotogrammetry, measurements for Go-Go and Zy-Zy displayed an interclass correlation coefficient (ICC) of less than 0.75. Significant differences between the 2 methods were observed for En-En, Ex-Ex, and Go-Go ( P < 0.05). Specifically, CT analysis for Go-Go showed a measurement 2.34 mm larger than that obtained with the 3dMD method.

CONCLUSION

Both CT and stereophotogrammetry were found to be reliable methods for evaluating facial soft tissue. It is speculated that Go-Go measurement is primarily influenced by factors such as different positions, facial expressions, and gravity. These variables should be carefully considered during the evaluation of the mandibular angle region.

摘要

背景

本研究旨在探讨立体摄影测量和 CT 在三维人体测量面部分析中的可靠性和可重复性,并探索仰卧位 CT 的临床应用。

方法

本研究对 20 名健康志愿者进行了 3D CT 和 3dMD 立体摄影测量。测量了立体摄影测量和 CT 扫描在标志点之间的拟合距离,以及面部特征测量(Al-Al)面宽(Go-Go、Zy-Zy、Ex-Ex)和半颜面高度(Sn-Gn)。采用组内相关系数(ICC)评估测量方法的可靠性和观察者间的一致性。配对 t 检验用于分析方法内的位移。

结果

发现颧点、鼻根点和前鼻棘点受不同位置的影响最小,更适合作为配准的标志点。CT 对所有指标均显示出良好的观察者间可靠性。在立体摄影测量中,Go-Go 和 Zy-Zy 的测量值 ICC 小于 0.75。两种方法之间在 En-En、Ex-Ex 和 Go-Go 上观察到显著差异(P<0.05)。具体而言,CT 分析得出的 Go-Go 测量值比 3dMD 方法得出的测量值大 2.34mm。

结论

CT 和立体摄影测量均被认为是评估面部软组织的可靠方法。推测 Go-Go 测量主要受不同位置、面部表情和重力等因素的影响。在评估下颌角区域时,应仔细考虑这些变量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验