Exploring consistent ratios in morphometry of the proximal tibia: insights for knee arthroplasty.

机构信息

Department of Anatomy, School of Medicine, Faculty of Health Sciences, National and Kapodistrian University of Athens, 75 Mikras Asias Street, Goudi, Athens, 11527, Greece.

Department of Orthopedics and Traumatology, Ankara Bilkent City Hospital, Ankara, 06000, Turkey.

出版信息

Surg Radiol Anat. 2024 Sep;46(9):1393-1399. doi: 10.1007/s00276-024-03421-x. Epub 2024 Jun 29.

Abstract

INTRODUCTION

The current study, which delves into proximal tibia morphometric parameters in a Greek sample, not only analyzes whether specific linear distance ratios are consistent but also paves the way for a potential novel metric system for knee arthroplasty imaging studies using constant ratios. These findings could have significant implications for future enlarged research and clinical practice.

METHODS

A total of 38 dried tibiae were evaluated by two independent investigators. The following distances were measured with a digital Vernier sliding caliper: (1) the mediolateral distance of the proximal surface (A), (2) the anteroposterior distance of the proximal surface (B), (3) The longitudinal length of the bone (C), (4) the line connecting the anterior margin of the proximal surface with the highest peak of the tibia tuberosity (D), (5) the depth of the proximal margin of the medial articular facet (AF) (medial plateau) (E) and (6) the depth of the proximal margin of the lateral AF (lateral plateau) (F).

RESULTS

The A, B, C, D, E, and F mean distances were 71.3 mm, 47.4 mm, 340.2 mm, 37.1 mm, 42 mm, and 35.9 mm. Reliability analysis for each observer on all measurements revealed an interclass correlation (ICC) score of 0.975 (observer 1) and 0.971 (observer 2). The ratio A/B was 1.5, A/C was a constant 0.2, and D/C was 0.1. The ratio E/F was 1.2. The six measurements (A-F) showed excellent inter-observer reliability (all ICC values > 0.990).

CONCLUSIONS

The study established constant ratios of the studied linear distances around the proximal tibia. Considering these ratios, asymmetrical tibial components in knee arthroplasty seem to replicate the native anatomy more closely. Furthermore, the distance from the anterior margin of the proximal surface to the tibial tuberosity peak, constituting one-tenth of the longitudinal length of the tibia, shows promise as a metric system for imaging studies, especially in assessing lesions around tibial components.

摘要

简介

本研究深入探讨了希腊人群胫骨近端形态计量参数,不仅分析了特定线性距离比是否一致,还为使用恒定比值的膝关节置换成像研究建立了潜在的新度量系统铺平了道路。这些发现可能对未来的扩大研究和临床实践具有重要意义。

方法

两位独立的研究人员评估了 38 个干燥胫骨。使用数字游标卡尺测量以下距离:(1)胫骨近端表面的内外径(A),(2)胫骨近端表面的前后径(B),(3)骨的纵向长度(C),(4)连接胫骨近端表面前缘与胫骨结节最高点的线(D),(5)内侧关节面近端边缘的深度(内侧平台)(E)和(6)外侧关节面近端边缘的深度(外侧平台)(F)。

结果

A、B、C、D、E 和 F 的平均距离分别为 71.3mm、47.4mm、340.2mm、37.1mm、42mm 和 35.9mm。对每位观察者的所有测量值进行可靠性分析,发现观察者 1 的组内相关系数(ICC)评分为 0.975,观察者 2 的 ICC 评分为 0.971。A/B 比值为 1.5,A/C 为恒定 0.2,D/C 为 0.1。E/F 比值为 1.2。六个测量值(A-F)显示出极好的观察者间可靠性(所有 ICC 值均大于 0.990)。

结论

本研究确定了胫骨近端周围研究线性距离的恒定比值。考虑到这些比值,膝关节置换中不对称的胫骨部件似乎更能复制原生解剖结构。此外,胫骨近端表面前缘到胫骨结节最高点的距离构成胫骨纵向长度的十分之一,有望成为成像研究的度量系统,特别是在评估胫骨部件周围的病变方面。