Suppr超能文献

标准吲哚菁绿与稀释吲哚菁绿之间的荧光强度用于评估大鼠皮瓣灌注情况

Fluorescence Intensity between Standard versus Diluted Indocyanine Green to Evaluate Flap Perfusion in Rats.

作者信息

Atmodiwirjo Parintosa, Ramadan Mohamad R, Sapphira Elrica, Djohan Michael, Ralena Nadhira A, Amanda Nadira F

机构信息

From the Division of Plastic Reconstructive and Aesthetic Surgery, Department of Surgery, Dr. Cipto Mangunkusumo National Referral Hospital, Faculty of Medicine Universitas Indonesia, Jakarta, Indonesia.

出版信息

Plast Reconstr Surg Glob Open. 2024 Jul 3;12(7):e5948. doi: 10.1097/GOX.0000000000005948. eCollection 2024 Jul.

Abstract

The ideal dose for indocyanine green (ICG) has not been established yet, although 5 mg per mL is widely accepted for free flap evaluation. Due to its high price and rarity in developing countries, this preliminary study aimed to find the lowest concentration of ICG without reducing the fluorescence quality read by near-infrared camera in animal models. An experimental study was conducted on 25 Wistar rats divided into five groups based on the injected ICG, which was in 5 mg per mL, 3.75 mg per mL, 2.5 mg per mL, 1.25 mg per mL, and 0.5 mg per mL concentrations. The epigastric flap was elevated and confirmed to be vital on the fifth day. Upon confirmation, bolus IV injection of ICG was given via the tail, and the flap was read using near-infrared camera. The 25 different videos are randomized and rated individually in a blind manner by five microsurgeons, chosen beforehand. The videos are evaluated with a scoring system ranging from 0 to 4, assessing fluorescence visibility and flap vasculature. Nonetheless, the intraclass correlation coefficient is 0.779. There was no difference between standard and diluted ICG concentrations to evaluate flap perfusion. The 2.5 mg per mL concentration of ICG was the most favorable. This finding is not clinically relevant for application in human subjects yet. However, this study shows promising results for further usage of ICG in daily practice at a lower cost.

摘要

尽管每毫升5毫克的吲哚菁绿(ICG)用于游离皮瓣评估已被广泛接受,但其理想剂量尚未确定。由于其价格高昂且在发展中国家较为罕见,这项初步研究旨在找到在动物模型中不降低近红外相机读取的荧光质量的最低ICG浓度。对25只Wistar大鼠进行了一项实验研究,根据注射的ICG浓度分为五组,浓度分别为每毫升5毫克、3.75毫克、2.5毫克、1.25毫克和0.5毫克。在第五天掀起腹壁皮瓣并确认其存活。确认后,经尾静脉推注ICG,然后使用近红外相机读取皮瓣情况。25个不同的视频由预先选定的五名显微外科医生以盲法随机单独评分。使用从0到4的评分系统对视频进行评估,评估荧光可见度和皮瓣血管分布。尽管如此,组内相关系数为0.779。在评估皮瓣灌注方面,标准浓度和稀释后的ICG浓度之间没有差异。每毫升2.5毫克的ICG浓度是最适宜的。这一发现目前在人体应用中尚无临床相关性。然而,这项研究显示了ICG在日常实践中以更低成本进一步应用的有前景的结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验