采用新型数字化 workflow 制作的一体式聚醚醚酮可摘局部义齿的临床评估:一项自身对照临床试验。

Clinical evaluation of a one-piece polyetheretherketone removable partial denture fabricated using a novel digital workflow: A self-controlled clinical trial.

机构信息

Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Beijing, China.

Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Beijing, China.

出版信息

J Prosthodont. 2024 Oct;33(8):757-763. doi: 10.1111/jopr.13907. Epub 2024 Jul 15.

Abstract

PURPOSE

To explore the clinical application of one-piece polyetheretherketone (PEEK) removable partial dentures (RPDs) fabricated using a novel digital workflow and to evaluate their weights and fits in vivo and patient satisfaction.

MATERIALS AND METHODS

Fifteen cases with posterior partially edentulous situations were selected, and each patient received two types of RPDs, including a novel digital workflow (test group) and a conventional workflow (control group). For the test group, one-piece RPDs were designed through three-dimensional (3D) methods by scanning stone casts and fabricated by milling PEEK discs. Each RPD was weighed. The gaps between the oral tissue and RPDs in each group were duplicated using a polyvinylsiloxane (PVS) replica and measured by 3D analysis. A visual analog scale (VAS) was used to evaluate the patient's satisfaction. Paired t-tests were used to compare the differences in the weight, the gaps of each RPD, and VAS values between the two groups. One-way analysis of variance tests was used to compare the differences in the gap among different components in each group.

RESULTS

The RPD in the test group weighed less than that in the control group (p < 0.01). No statistically significant differences in the gaps of denture bases and rests (p > 0.05) were found between the two groups, but the gaps of major connectors in the test group were significantly smaller than in the control group (p < 0.05). The VAS scores for comfortableness and masticatory efficiency were not significantly different between the two groups (p > 0.05) but the scores for the aesthetic appearance of the clasps in the test group were significantly higher than that in the control group (p < 0.05).

CONCLUSIONS

One-piece PEEK RPDs manufactured using a novel digital workflow weighed less than conventional RPDs and exhibited a clinically acceptable internal fit. Although the aesthetic appearance of the PEEK clasps was superior to the control, there is still room for improvement.

摘要

目的

探索新型数字化工作流程制作的一体式聚醚醚酮(PEEK)可摘局部义齿(RPD)的临床应用,并评估其体内重量、适合度和患者满意度。

材料与方法

选择 15 例后牙部分缺失的患者,每位患者接受两种 RPD,包括新型数字化工作流程(实验组)和传统工作流程(对照组)。实验组通过扫描石膏模型的三维(3D)方法设计一体式 RPD,并通过铣削 PEEK 圆盘制作。每个 RPD 均称重。通过聚硅氧烷(PVS)复制体复制每组 RPD 与口腔组织之间的间隙,并通过 3D 分析进行测量。采用视觉模拟评分(VAS)评估患者满意度。采用配对 t 检验比较两组间 RPD 重量、各 RPD 间隙和 VAS 值的差异。采用单因素方差分析比较每组不同部件间隙的差异。

结果

实验组 RPD 重量小于对照组(p<0.01)。两组基托和支托间隙无统计学差异(p>0.05),但实验组主要连接体间隙明显小于对照组(p<0.05)。两组舒适度和咀嚼效率的 VAS 评分无显著差异(p>0.05),但实验组卡环美观度评分明显高于对照组(p<0.05)。

结论

新型数字化工作流程制作的一体式 PEEK RPD 重量小于传统 RPD,具有临床可接受的内部适合度。虽然 PEEK 卡环的美观度优于对照组,但仍有改进空间。