Suppr超能文献

研究405纳米波长二极管激光作为常规牙科诊断工具的疗效。

Examining the Efficacy of a 405 nm Wavelength Diode Laser as a Diagnostic Tool in Routine Dental Practice.

作者信息

El Mobader Marwan, Nammour Samir

机构信息

Department of Oral Surgery, Laser Laboratory, Wroclaw Medical University, Wroclaw, POL.

Department of Dental Sciences, Faculty of Medicine, University of Liege, Liege, BEL.

出版信息

Cureus. 2024 Jun 16;16(6):e62474. doi: 10.7759/cureus.62474. eCollection 2024 Jun.

Abstract

In recent years, significant advancements in dental and periodontal diagnostics have paved the way for improved care. Among the available approaches, laser fluorescence (LF) is a promising method. This case report explores the utilization of a 405 nm diode laser as a diagnostic tool in the non-surgical treatment of biofilm-induced gingivitis, as well as its application in routine daily practice for diagnosing restorations and dental caries. A 24-year-old male patient and a 21-year-old female patient were included. A 405 nm diode laser (Smart M, Lasotronix, Poland) was used as a diagnostic tool with a tip diameter of 8 mm. In case one, the utilization of the 405 nm diode laser enhanced the patient's ability to perceive the presence and extent of plaque and calculus, aiding in motivation and education regarding supra-gingival dental biofilm control and it assisted the operator in precisely localizing plaque and calculus, thereby enabling more effective mechanical debridement and ultimately improving treatment outcomes. In the second case, the utilization of the laser facilitated the detection of defective composite fillings aiding in both accurate diagnosis for the operator and effective communication with the patient regarding the need for re-treatment. This study illustrates the potential of the relatively new 405 nm diode laser as a promising diagnostic tool in the daily management of periodontal patients and the detection of defective dental fillings in daily practice.

摘要

近年来,牙科和牙周诊断技术取得了重大进展,为改善治疗奠定了基础。在现有的方法中,激光荧光(LF)是一种很有前景的方法。本病例报告探讨了405nm二极管激光作为诊断工具在生物膜性牙龈炎非手术治疗中的应用,以及其在日常实践中诊断修复体和龋齿的应用。纳入了一名24岁男性患者和一名21岁女性患者。使用了一台尖端直径为8mm的405nm二极管激光(Smart M,Lasotronix,波兰)作为诊断工具。在第一个病例中,405nm二极管激光的使用增强了患者感知牙菌斑和牙结石的存在及范围的能力,有助于提高患者对龈上牙菌斑控制的积极性和相关教育,并且协助操作人员精确地定位牙菌斑和牙结石,从而实现更有效的机械清创,最终改善治疗效果。在第二个病例中,激光的使用有助于检测复合树脂充填体的缺陷,既有助于操作人员进行准确诊断,也有助于就再次治疗的必要性与患者进行有效沟通。本研究说明了相对较新的405nm二极管激光作为一种有前景的诊断工具在牙周病患者日常管理及日常实践中检测有缺陷的补牙方面的潜力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f120/11251338/329cd6742264/cureus-0016-00000062474-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验