Carotid web catheter angiography hemodynamic parameters.

作者信息

Damiani Monteiro Mateus, Tarek Mohamed A, Martins Pedro N, Allen Jason W, Nogueira Raul G, Landzberg David, Dolia Jaydevsinh, Park Charlie Chulhyun, Liberato Bernardo, Frankel Michael R, Haussen Diogo C

机构信息

Department of Neurology, Emory University School of Medicine, Atlanta, Georgia, USA.

Marcus Stroke and Neuroscience Center, Grady Memorial Hospital, Atlanta, Georgia, USA.

出版信息

J Neurointerv Surg. 2025 Jul 14;17(8):843-847. doi: 10.1136/jnis-2024-021948.

Abstract

BACKGROUND

Carotid web (CaW)-related contrast stagnation on digital subtraction angiography (DSA) may be a marker supporting the pathophysiological theory of stasis and thrombosis/embolization. We aim to assess the correlation between DSA hemodynamic parameters with CT angiography (CTA) structural measurements and clinical characteristics.

METHODS

Cross-sectional analysis of consecutive patients with CaW who underwent CTA+DSA. DSA-derived hemodynamic parameters were calculated based on a region of interest at the carotid bulb (time-density curves; TDC). The correlation between duration of contrast stagnation with CaW structural features and with clinical characteristics was evaluated with a mixed effects model.

RESULTS

Sixty patients of mean±SD age 52.2±10.3 years were included, of whom 38 (63.3%) were women, 51 (85%) were black, and 59 (98.3%) had symptomatic lesions. The median CaW base was 2.46 mm (range 1.95-3.76), length 2.7 mm (range 2.15-3.96), thickness (length/base) 1.05 (IQR 0.81-1.36), caudal angle 31.93° (IQR 22.35-43.58), mean±SD distal angle 66.91±15.84°, pocket area 1.62 mm² (0.96-1.62), and pocket perimeter 6.03±2.6 mm. The TDC consistently showed an initial fast decay from the peak concentration followed by a plateau with a negative exponential pattern. The median stagnation time from peak density to 80% contrast clearance was 2.91 s (range 1.81-4.94). No significant associations were observed between the stagnation time and CaW CTA structural measurements (length/base/thickness, caudal and cranial angles web surface angles, web pocket area/perimeter) or clinical characteristics.

CONCLUSIONS

A negative exponential pattern in the DSA contrast clearance of the CaW pocket was observed. There were no morphological or clinical features clearly associated with the duration of contrast stagnation on DSA. The hemodynamic disruption caused by CaW and its thrombotic risk may not be appropriately measured by contrast stagnation time.