Henderson P N
Arch Ophthalmol. 1985 Oct;103(10):1582-5. doi: 10.1001/archopht.1985.01050100158041.
The functional success of a Jones Pyrex tube depends on the accurate positioning of the tube. The modified trephining technique for the insertion of a Jones tube ensures accurate positioning by using a guide wire to maintain the selected position and direction of the tube while a 1.5-mm-diameter trephine cuts a cylindrical track around the guide wire, down which a straight Pyrex tube is threaded. The snug fit between the tube and the trephined track has minimized postoperative extrusion (5%) and migration (7%). This technique has been used to insert 93 tubes in 84 patients aged 7 to 83 years.
琼斯派热克斯玻璃管的功能成功取决于管子的精确放置。用于插入琼斯管的改良环钻技术通过使用导丝来确保精确放置,在直径为1.5毫米的环钻围绕导丝切割出圆柱形通道时,导丝可维持管子选定的位置和方向,一根直的派热克斯玻璃管沿此通道穿入。管子与环钻通道之间的紧密配合使术后挤压(5%)和移位(7%)降至最低。该技术已用于为84例年龄在7至83岁的患者插入93根管子。