Suppr超能文献

高效液相色谱法测定林可霉素在肉鸡血浆中浓度及其药代动力学研究。

Validation of the method for determining lincomycin levels and calculating lincomycin levels in broiler chicken plasma using high-performance liquid chromatography.

机构信息

Veterinary Science Doctoral Program, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Yogyakarta, Indonesia.

Department of Pharmacology, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Yogyakarta, Indonesia.

出版信息

Open Vet J. 2024 Jun;14(6):1453-1459. doi: 10.5455/OVJ.2024.v14.i6.13. Epub 2024 Jun 30.

Abstract

BACKGROUND

Antibiotic residues that come from food of animal origin, such as broiler chicken, have a variety of consequences on human health and increase the likelihood of antibiotic resistance. Lincomycin residue investigations in broiler chicken especially in plasma broiler chicken should be undertaken utilizing the validation method analysis.

AIM

The purpose of this study is to determine the high-performance liquid chromatography (HPLC) as a validation method for calculating the residual concentration of lincomycin in broiler chicken blood plasma and compare it with the minimum Inhibitor Concentration (MIC) and Maximum Residue Limits (MRLs) standards for lincomycin.

METHODS

Thirty-five-day-old broiler chickens cobb 700 were weighed and randomly allocated to and separated into control (placebo) and six treatment groups of varying doses and duration. The treatment group's suggested dosage of lincomycin was 50, 100, or 150 mg/kg/day given to 18-day-old chicken, along with drinking water for a week (A group) and 2 weeks (P group). Lincomycin levels in blood plasma were validated using HPLC. The residual lincomycin concentrations 24 hours and 1 week after injection were compared to the lincomycin MIC and the Indonesian National Standard of MRL.

RESULT

The validation of linscomycin reveals a linear value in blood plasma with an R of 0.9983. Precision and accuracy levels indicate promising results for detecting lincomycin. The retention duration for 100 µg/ml lincomycin was 10.0-10.5 minutes. Lincomycin had LOD and LOQ values of 13.98 and 4.86 µg/ml, respectively. After 1 week of dosing at 50 and 100 mg/kg dosages, lincomycin residue detection was 0.00, which was below the MRL criterion of <0.1 ppm. The study found that the residual concentration of 150 mg/kg dosages for a week and 100/150 mg/kg doses for 2 weeks above the lincomycin MIC limits against .

CONCLUSION

Lincomycin detection by HPLC in chicken blood plasma showed promising results in terms of linearity, accuracy, precision, specificity, and sensitivity. Lincomycin administration for 1 week at doses of 50 and 100 mg/kg resulted in the lowest residual concentration below the lincomycin MIC and MRL standards.

摘要

背景

动物源性食品(如肉鸡)中的抗生素残留会对人类健康造成多种影响,并增加抗生素耐药性的可能性。因此,应利用验证方法分析来检测肉鸡,尤其是血浆肉鸡中的林可霉素残留。

目的

本研究旨在确定高效液相色谱法(HPLC)作为计算肉鸡血浆中林可霉素残留浓度的验证方法,并将其与林可霉素的最低抑菌浓度(MIC)和最大残留限量(MRL)标准进行比较。

方法

将 35 日龄科宝 700 肉鸡称重并随机分配到对照组(安慰剂)和 6 个不同剂量和持续时间的治疗组。治疗组建议的林可霉素剂量为 18 日龄鸡 50、100 或 150mg/kg/天,同时饮用含药饮水 1 周(A 组)和 2 周(P 组)。采用 HPLC 法对血浆中的林可霉素进行验证。比较注射后 24 小时和 1 周时的残留林可霉素浓度与林可霉素 MIC 和印度尼西亚国家标准 MRL 的关系。

结果

林可霉素的验证显示,其在血浆中的线性值为 0.9983,R2 值高。精密度和准确度水平表明,检测林可霉素的结果具有较好的前景。林可霉素 100µg/ml 的保留时间为 10.0-10.5 分钟。林可霉素的检出限和定量限分别为 13.98µg/ml 和 4.86µg/ml。50mg/kg 和 100mg/kg 剂量连续给药 1 周后,林可霉素残留检测结果为 0.00,低于 MRL 标准<0.1ppm。研究发现,1 周 150mg/kg 剂量和 2 周 100/150mg/kg 剂量的林可霉素残留浓度超过林可霉素 MIC 限值。

结论

HPLC 检测鸡血浆中的林可霉素在线性、准确性、精密度、特异性和灵敏度方面均表现出较好的结果。1 周内 50mg/kg 和 100mg/kg 剂量给药可使林可霉素残留浓度降至最低,低于林可霉素 MIC 和 MRL 标准。