Ko Young-Chang, Koo Ki-Tae, Li Ling, Lee Dongseob, Lee Yong-Moo, Seol Yang-Jo, Kim Tae-Hyung, Lee Jungwon
Department of Periodontology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Korea.
National Dental Care Center for Persons with Special Needs, Seoul National University Dental Hospital, Seoul, Korea.
J Periodontal Implant Sci. 2025 Feb;55(1):50-61. doi: 10.5051/jpis.2400800040. Epub 2024 Jul 10.
This study investigated the effect of implant vertical positioning within alveolar ridge preservation (ARP) sites on implant stability quotient (ISQ) values, which were measured 10 weeks post-implantation.
Patients who underwent ARP using collagenized deproteinized bovine bone mineral, followed by implant placement in the posterior area, were divided into 2 groups: the within-ARP group and the beyond-ARP group. In the within-ARP group, osteotomy and implant placement occurred within the ARP boundary. In contrast, in the beyond-ARP group, these procedures were performed beyond the ARP boundary, incorporating 3 mm of pristine bone at the implant's apex. Bone quality was assessed by tactile sense, and both insertion torque during implant surgery and ISQ values at 10 weeks post-implant surgery were measured. Multiple linear regression analysis and Pearson correlation analysis were used to explore the relationship between insertion torque and ISQ values.
In total, 30 ARP sites in 28 patients were analyzed. There was no significant difference in bone quality, as determined by tactile sense, between the within-ARP and beyond-ARP groups. At the time of implant placement, the beyond-ARP group exhibited a higher insertion torque (33.33±13.39 Ncm) compared to the within-ARP group (17.08±11.17 Ncm). However, the ISQ values were similar between the 2 groups 10 weeks after implant placement. A positive correlation between insertion torque and ISQ values was confirmed at 10 weeks post-implant.
The engagement of pristine bone may facilitate high insertion torque during the placement of implants in ARP sites. Nevertheless, by 10 weeks post-implantation, the ISQ values were found to be comparable, irrespective of the implant's position.
本研究调查了牙槽嵴保存(ARP)位点内种植体垂直定位对种植体稳定性商数(ISQ)值的影响,ISQ值在种植后10周进行测量。
使用胶原化脱蛋白牛骨矿物质进行ARP,随后在后部区域植入种植体的患者被分为2组:ARP内组和ARP外组。在ARP内组中,截骨术和种植体植入在ARP边界内进行。相比之下,在ARP外组中,这些操作在ARP边界之外进行,在种植体顶端纳入3mm的原始骨。通过触觉评估骨质量,并测量种植手术期间的插入扭矩和种植手术后10周的ISQ值。使用多元线性回归分析和Pearson相关性分析来探讨插入扭矩与ISQ值之间的关系。
总共分析了28例患者的30个ARP位点。通过触觉确定,ARP内组和ARP外组之间的骨质量没有显著差异。在种植体植入时,ARP外组的插入扭矩(33.33±13.39 Ncm)高于ARP内组(17.08±11.17 Ncm)。然而,种植体植入10周后,两组的ISQ值相似。在种植后10周证实插入扭矩与ISQ值之间存在正相关。
原始骨的参与可能有助于在ARP位点植入种植体时获得高插入扭矩。然而,到种植后10周时,发现无论种植体位置如何,ISQ值都是可比的。