Pontaema Theerapong, Pongthaisong Pongphol, Kenchaiwong Wootichai, Chompoosan Chayanon, Lerdweeraphon Wichaporn
Applied Animal Physiology Research Unit, Faculty of Veterinary Science, Mahasarakham University, Mahasarakham, 44000, Thailand.
Small Ruminant Research Unit, Faculty of Veterinary Science, Mahasarakham University, Mahasarakham, 44000, Thailand.
Vet World. 2024 Jun;17(6):1385-1390. doi: 10.14202/vetworld.2024.1385-1390. Epub 2024 Jun 28.
Vasovagal tonus index (VVTI) serves as a straightforward assessment tool for autonomic function during both physiological and pathological conditions, including pregnancy, in horses. Obtaining VVTI through a modified base apex lead system could be a practical and comfortable solution. In this study, we assessed VVTI in horses with respect to training status and electrocardiographic measurements utilizing a novel modified base apex lead technique.
A total of 12 Thai native crossbred horses and 12 Arabian horses, all free of cardiac abnormalities, were enrolled in the study. Animals underwent electrocardiogram (ECG) and VVTI using both the base-apex lead method and its modified version. 25 mm/s and 10 mm/mV ECG recordings provided standard bipolar limb leads. The amplitudes and durations of P waves, QRS complexes, PR interval, QT interval, and T duration were assessed. The T wave's shape was examined. Each recording's R-R interval was utilized to assess heart rate. Twenty consecutive beats were used to compute the variability of heart rate (VVTI).
The P wave amplitude was the only significant difference (p < 0.05) between the base apex lead method and the modified base apex lead method, with no variations in heart rate, P duration, PR interval, T duration, and QRS duration and amplitude. Both methods showed mainly biphasic T wave patterns. The VVTI values of all horses did not differ significantly between the base apex and modified base apex methods. There was no significant difference in VVTI between Thai crossbred horses and Arabian horses in either method.
This study provided the first evidence that VVTI can be evaluated using the modified base apex lead system and may be useful for cardiovascular function monitoring in horses.
血管迷走张力指数(VVTI)是评估马匹在生理和病理状态(包括妊娠)下自主神经功能的一种直接方法。通过改良的基顶导联系统获取VVTI可能是一种实用且舒适的解决方案。在本研究中,我们利用一种新型改良基顶导联技术,就训练状态和心电图测量对马匹的VVTI进行了评估。
本研究共纳入12匹泰国本地杂交马和12匹阿拉伯马,所有马匹均无心脏异常。动物接受了心电图(ECG)检查,并使用基顶导联法及其改良版本测量了VVTI。以25mm/s和10mm/mV的心电图记录提供标准双极肢体导联。评估了P波、QRS波群、PR间期、QT间期和T波时限的幅度和时长。检查了T波的形态。利用每次记录的R-R间期评估心率。使用连续20个心搏计算心率变异性(VVTI)。
基顶导联法与改良基顶导联法之间,仅P波幅度存在显著差异(p<0.05),心率、P波时限、PR间期、T波时限以及QRS波群的时限和幅度均无变化。两种方法主要显示双相T波形态。所有马匹的VVTI值在基顶导联法与改良基顶导联法之间无显著差异。在两种方法中,泰国杂交马和阿拉伯马的VVTI均无显著差异。
本研究首次证明,可使用改良基顶导联系统评估VVTI,其可能有助于监测马匹的心血管功能。