Mohr Arno, Zahn Stefanie, Geismann Florian, Blaas Stefan, Pfeifer Michael, Malfertheiner Maximilian, Salzberger Bernd, Hanses Frank, Bauernfeind Stilla, Koch Myriam, Hitzenbichler Florian
Pneumologie, Infektiologie, Beatmungsmedizin, InnKlinikum gKU Altötting und Mühldorf, Mühldorf, Germany.
Klinik und Poliklinik für Innere Medizin II, Universitätsklinikum Regensburg, Regensburg, Germany.
Pneumologie. 2025 Apr;79(4):292-296. doi: 10.1055/a-2361-4723. Epub 2024 Jul 30.
Face masks increase airway resistance, data on the actual extent of this effect are scarce. The aim of this study was to assess the effect of different mask types on clinical parameters during moderate exercise in healthy non-smokers, active smokers and patients with interstitial lung disease (ILD) without the need of oxygen therapy.In a prospective observational pilot study participants performed a six-minute walk test without mask, with a surgical mask, a well-fitted FFP2 mask and with a valved FFP3 mask. Respiratory rate, blood pressure, heart rate, blood gas analysis parameters, dyspnoea and six-minute walk distance were measured. Data were analysed in an ANOVA model.21 healthy participants, 17 active smokers without known pulmonary disease and 15 patients with interstitial lung disease were included. Participants with ILD had a significant lower walking distance, a higher respiratory rate and a lower pO when using FFP2 masks, but not with valved FFP3 masks or surgical masks compared to not wearing a mask.For patients with ILD without the need of oxygen therapy wearing an FFP2 mask had a negative impact on pO, respiratory rate and walking distance in the six-minute walk test. This effect was not seen with valved FFP3 masks or surgical masks.
口罩会增加气道阻力,但关于这种影响实际程度的数据却很稀少。本研究的目的是评估不同类型口罩对健康非吸烟者、现役吸烟者和无间质性肺病(ILD)且无需氧疗的间质性肺病患者在适度运动期间临床参数的影响。
在一项前瞻性观察性试点研究中,参与者分别在不戴口罩、佩戴外科口罩、佩戴贴合良好的FFP2口罩和佩戴带阀FFP3口罩的情况下进行六分钟步行测试。测量呼吸频率、血压、心率、血气分析参数、呼吸困难程度和六分钟步行距离。数据在方差分析模型中进行分析。
纳入了21名健康参与者、17名无已知肺部疾病的现役吸烟者和15名间质性肺病患者。与不戴口罩相比,ILD患者在佩戴FFP2口罩时步行距离显著缩短、呼吸频率更高且pO更低,但佩戴带阀FFP3口罩或外科口罩时则不然。
对于无需氧疗的ILD患者,在六分钟步行测试中,佩戴FFP2口罩对pO、呼吸频率和步行距离有负面影响。而佩戴带阀FFP3口罩或外科口罩时未观察到这种影响。