Suppr超能文献

ICDAS 临床标准在数字 3D 模型上的诊断准确性。

Diagnostic validity of ICDAS clinical criteria on digital 3D models.

机构信息

Department of Pediatric Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes, 2227 - Cidade Universitária, São Paulo SP, 05508-000, Brasil; Department of Odontology, University of Copenhagen, Nørre Allé 20, DK-2200 Copenhagen N, Denmark.

Department of Odontology, University of Copenhagen, Nørre Allé 20, DK-2200 Copenhagen N, Denmark.

出版信息

J Dent. 2024 Oct;149:105274. doi: 10.1016/j.jdent.2024.105274. Epub 2024 Jul 29.

Abstract

OBJECTIVE

To assess the diagnostic validity of ICDAS clinical criteria on 3D dental models from intraoral scanning.

METHODS

This is a retrospective analysis on part of the baseline sample collected in a cohort study and included 73 participants (12-19 years) from Denmark and Greece. The assessment was made by visual inspection, and then by visual inspection associated with radiographs. All participants were scanned with TRIOS 4 which uses white light to obtain the 3D models with tooth color, as well as blue light source (415 nm) for fluorescence. The 3D models' evaluation was conducted using tooth-color texture and subsequently fluorescence. Two scores were obtained for the 3D model examination: i) ICDAS based on tooth-color information; ii) ICDAS based on tooth-color information supplemented with fluorescence. For the analysis, weighted kappa, sensitivity (SE), specificity (SP) and accuracy (ACC) were calculated.

RESULTS

Regarding all lesions the values for SE, SP, and ACC were respectively 0.804, 0.801, and 0.802 for tooth-color, and 0.819, 0.808, and 0.810 for tooth-color supplemented with fluorescence. In terms of accuracy parameters for moderate-extensive lesions, the values for SE, SP, and ACC for tooth color were 0.709, 0.948, and 0.944, while for fluorescence they were 0.815, 0.937, and 0.934.

CONCLUSION

Caries assessment with ICDAS criteria on 3D dental models produces reliable scores. Visual caries analysis using 3D models demonstrates commendable diagnostic accuracy and reasonable consistency with traditional methods. The use of intraoral scanners may be beneficial in evaluating occlusal caries.

CLINICAL SIGNIFICANCE

The importance of this study is to prove the diagnostic accuracy of caries lesions diagnosis made using and intraoral scanner and to offer greater confidence to professionals who use this diagnosis tool in their daily clinical practice. Intraoral scanners demonstrate to be an accurate tool for diagnosing occlusal caries.

摘要

目的

评估 ICDAS 临床标准在口腔内扫描的 3D 牙模上的诊断准确性。

方法

这是一项回顾性分析,基于一项队列研究的基线样本,包括来自丹麦和希腊的 73 名(12-19 岁)参与者。评估方法为视觉检查,然后是视觉检查结合射线照相。所有参与者均使用 TRIOS 4 进行扫描,该扫描仪使用白光获取具有牙齿颜色的 3D 模型,以及使用蓝光(415nm)获取荧光。使用牙齿颜色纹理和随后的荧光对 3D 模型进行评估。为 3D 模型检查获得了两个分数:i)基于牙齿颜色信息的 ICDAS;ii)基于补充荧光的牙齿颜色信息的 ICDAS。进行分析时,计算了加权 kappa、敏感性(SE)、特异性(SP)和准确性(ACC)。

结果

对于所有病变,基于牙齿颜色的 SE、SP 和 ACC 分别为 0.804、0.801 和 0.802,基于补充荧光的牙齿颜色的 SE、SP 和 ACC 分别为 0.819、0.808 和 0.810。在中-重度病变的准确性参数方面,基于牙齿颜色的 SE、SP 和 ACC 值分别为 0.709、0.948 和 0.944,而基于荧光的 SE、SP 和 ACC 值分别为 0.815、0.937 和 0.934。

结论

使用 ICDAS 标准对 3D 牙模进行龋齿评估可产生可靠的分数。使用 3D 模型进行龋齿分析显示出令人赞赏的诊断准确性,并且与传统方法具有合理的一致性。使用口腔内扫描仪可能有益于评估咬合面龋齿。

临床意义

这项研究的重要性在于证明了使用口腔内扫描仪诊断龋齿病变的准确性,并为在日常临床实践中使用这种诊断工具的专业人员提供了更大的信心。口腔内扫描仪被证明是一种准确的诊断工具,用于诊断咬合面龋齿。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验